Lead acid batteries with armour plated cells and liquid
electrolyte
4.1

Description

Jungheinrich traction batteries are lead acid batteries with armour plated cells and
liquid electrolyte. The names of the traction batteries are PzS, PzB, PzS Lib and PzM.
Electrolyte
The rated density of the electrolyte assumes a temperature of 30°C and the rated
electrolyte level is fully charged. Higher temperatures will reduce, lower temperatures
will increase the electrolyte density. The adjustment factor is ± 0.0007 kg/l per K, e.g.
electrolyte density 1.28 kg/l at 45°C corresponds to a density of 1.29 kg/l at 30°C.
The electrolyte must conform to DIN 43530 Part 2 purity regulations.
4.1.1 Battery nominal data
1.
Product
2.
Nominal voltage
3.
Rated capacity C5
4.
Discharge current
5.
Nominal electrolyte density
6.
Nominal temperature
7.
System rated electrolyte level
Limit temperature
1. Reached within the first 10 cycles.
2. Higher temperatures shorten the useful life, lower temperatures reduce
the available capacity.
3. Not permissible as operating temperature.
4
Traction battery
2.0 V x no. of cells
See data plate
C5/5h
1
1.29 kg/l
2
30 °C
up to "Max" electrolyte level marking
3
55°C