4
Lead acid batteries with armour plated cells and liquid
electrolyte
4.1
Description
Jungheinrich traction batteries are lead acid batteries with armour plated cells and
liquid electrolyte. The names of the traction batteries are PzS, PzB, PzS Lib and
PzM.
Name
PzS
PzB
PzS Lib
PzM
Electrolyte
The rated density of the electrolyte assumes a temperature of 30°C and the rated
electrolyte level is fully charged.
temperatures will increase the electrolyte density.
The corresponding adjustment factor is ± 0.0007 kg/l per K, e. g. electrolyte density
1.28 kg/l at 45 °C corresponds to a density of 1,29 kg/l at 30 °C.
The electrolyte must comply with the purity regulations of DIN 43530 Part 2.
Explanation
– Lead acid battery with "Standard" armour plated cells and liquid
electrolyte
– Battery cell width: 198 mm
– Lead acid battery with "British Standard" armour plated cells
and liquid electrolyte
– Battery cell width: 158 mm
– Lead acid battery with "Standard" armour plated cells and liquid
electrolyte
– Lead acid battery with extended maintenance interval
– Battery cell width: 198 mm
Higher temperatures will reduce, lower
151