Make sure your PC and network do not have a software firewall program that might
block the IP address of the IPCP unit.
3.
If contact is established with the unit, but the IPCP Web pages cannot be accessed
by your Web browser, verify (via an Internet network options or preferences menu) that
your Web browser is configured for direct network connection and is not set up to use a
proxy server.

Device Control Connections and Configuration

Verify that ports are wired correctly and that ground (earthing) wires are connected to
the proper pins on the control processor and, if applicable, on the controlled device.
Ensure that each IR emitter head is placed adjacent to or directly over the IR pickup
window on the controlled device.
Verify that the appropriate drivers were used while creating the configuration file and that
the correct commands and signal types (IR, RS-232, Ethernet) are associated with the
appropriate ports on the control processor and on the other devices.
For digital input and output connections, verify whether the application requires the
+5 VDC pull-up resistor within the IPCP for TTL circuits and use the software to check
whether it is selected within the configuration.
Verify that input current at any digital input or output port does not exceed 250 mA.
Verify that input current at the volume control port (IPCP Pro 250) does not exceed
10 VDC and that the amplifier is cabled correctly, as well.
If you are still experiencing problems, call the
Hotline
or the Extron S3 Control Systems Support Hotline (1.800.633.9877).