This receiver accepts infrared signals of from 30 kHz to 300 KHz. The IR remote control
must be pointed directly at the receiver for best results. The front panel diagram (see
figure 5) indicates the best distances and angles at which to hold the remote control.
NOTE: The IPCP 350M does not have an IR learning sensor.

Reset Features

Reset button and LED — Pressing this recessed button causes various product settings
to be reset to the factory defaults. The green power LED flashes depending on the selected
reset mode (see
page 22 for details).
Mounting the IPCP Pro Series

Mounting Options

Optional 1U high rack shelves and a variety of rack mounting bracket kits and furniture
mounting kits are available for use with the IPCP Pro models. Visit the product-specific
page on the Extron website for a list of compatible accessories for mounting your control
processor or call a support representative to find out which kit to order for your installation.
Read the instructions that are included with the rack shelf or mounting kit for installation
procedures and see the UL rack mounting guidelines (below) for safe installation.

UL Rack Mounting Guidelines

The following
IPCP Pro Series control processors in a rack.
1.
2.
3.
4.
5.
Resetting the Unit
Underwriters Laboratories (UL)
Elevated operating ambient temperature — If installed in a closed or multi-unit
rack assembly, the operating ambient temperature of the rack environment may be
greater than room ambient temperature. Therefore, install the IPCP in an environment
compatible with the maximum ambient temperature (Tma = +122 °F, +50 °C) specified
by Extron.
Reduced air flow — Install the equipment in a rack so that the amount of air flow
required for safe operation of the equipment is not compromised.
Mechanical loading — Mount the equipment in the rack so that a hazardous
condition is not achieved due to uneven mechanical loading.
Circuit overloading — Connect the equipment to the supply circuit and consider the
effect that circuit overloading might have on overcurrent protection and supply wiring.
Appropriate consideration of equipment nameplate ratings should be used when
addressing this concern.
Reliable earthing (grounding) — Maintain reliable grounding of rack-mounted
equipment. Pay particular attention to supply connections other than direct connections
to the branch circuit (such as use of power strips).
on page 22 and the
reset modes table
guidelines pertain to the safe installation of
IPCP Pro Series • Hardware Features and Installation