3. Enter the installer or dealer access code.
4. From the Configuration & Programming screen press DEVICES.
5. From the Devices screen select Outputs and press EDIT.
6. Press + ADD.
7. Change Output Type to Warning Siren.
8. Change Output Location to either OUT1 or OUT 2, depending upon how the warning siren is connected.
9. Press SAVE then press SAVE again.
10. Press CLOSE twice to return to the Configuration & Programming screen.
Note: For UL 1635 installations, entry delay plus dialer abort delay must not exceed 60 seconds.
Table 9 describes programming requirements to meet ANSI/SIA CP-01-2010.
Table 9: ANSI/SIA CP-01-2010 Setting Requirements and Nonprogrammable System Operation
Function
Entry Delay
Exit Delay
Auto Stay Arm
Abort Delay
Call Waiting
System Test
Communication Test
Exit Time Restart
Swinger Shutdown
Fire Verification
Duress/Panic Code
Cancel Report
Annunciation
Abort Annunciation
Silent Exit
Remote Arming Exit
Time/ Progress
Annunciation
Cancel Report
Annunciation
Recent Closing
Cross Zoning
Cross Check Timer
Exit Error
Restoration of Power
Swinger Trips
Fire Verification
Call waiting cancel
Alarm Cancel Window
Cancel Alarm
AdvisorOne Panel Quick Installation Guide
Default setting
30 seconds
60 seconds
Enabled
30 seconds
Off
Enabled
Enabled
Enabled
On (two trips)
Off
Disabled
Enabled
Enabled
Non-Programmable
Enabled
Enabled
Non-Programmable
Disabled
Disabled
Non-Programmable
Non-Programmable
Two
Disabled
Disabled
Non-Programmable
Enter Code Only
12 / 12 AdvisorOne Installation Guide
Required setting
Minimum of 30 seconds
60 seconds
Enabled
1 to 45 seconds (an aborted alarm will result in audible
and visual annunciation)
On if reporting to central station and customer has call
waiting service (PSTN only)
Enabled
Enabled
Enabled
On (two trips)
On (2 different sensors going into alarm within 210
seconds or 1 sensor going into alarm with 1 minute
repeat will cause a CS report.)
Disabled
Enabled
Enabled
All annunciators enabled
All annunciators enabled
Remote Arming not investigated by UL
Enabled
Enabled (2-minute window)
Enabled and 2 or more zones programmed Each zone
has the ability of individually protecting a cross-zoned
area (over-lapping area of two protective zones).
Enabled (set to 2 minutes)
Enabled
Panel resumes operation in same arming state and
disregards alarm signals from sensors for the first 60
seconds after power restoration
Enabled (all zones)
Enabled unless sensors can self-verify
Enabled if user has call waiting
Enabled (factory set to 5 minutes)
Enter code only
17 / 18