The 34HM-35HM IDH Max Mortise Lock provides the fol-
lowing features in an integrated lock, eliminating the
need to install separate sensors in and around the door
frame:
electrified locking mechanism
electronic token reader
integrated trim
door status detection
latchbolt status detection
ability to exit without triggering an alarm
The figure below shows the relationship between the
components in the IDH Max system.
T81600 Rev A 1919380 ER-7991-12 July 2006
Installation Instructions for
IDH Max 1300 Mortise Locks
Power
Power (2)
supply
RS-485 Communication (2)
Field wire
harness
Wire
Lock
transfer
hinge
BEST ACCESS SYSTEMS
A Division of Stanley Security Solutions, Inc
Contents
These installation instructions describe how to install,
wire, and configure the components provided with your
34HM-35HM IDH Max Mortise Lock. The following topics
are covered.
Site survey................................................................ 2
Components checklist............................................. 2
Special tools checklist ............................................. 3
Preparing the door and door jamb........................ 4
Installing the lock.................................................... 8
Testing the installation ......................................... 19
Troubleshooting the installation ......................... 20
B.A.S.I.S.
or
Lenel
Access
Control
Panel
1

Advertisement

loading

Summary of Contents for Best IDH Max 1300

  • Page 1: Table Of Contents

    Installation Instructions for IDH Max 1300 Mortise Locks Overview Contents The 34HM–35HM IDH Max Mortise Lock provides the fol- These installation instructions describe how to install, lowing features in an integrated lock, eliminating the wire, and configure the components provided with your need to install separate sensors in and around the door 34HM–35HM IDH Max Mortise Lock.
  • Page 2: Site Survey

    Installation Instructions for IDH Max 1300 Mortise Locks Site survey Use the following survey to record information about the Use the following checklist to make sure that you have the installation site. You need this information to determine items necessary to install the components provided with field wiring needs, select a power supply, and determine your 34HM–35HM IDH Max Mortise Lock.
  • Page 3: Components Checklist

    Installation Instructions for IDH Max 1300 Mortise Locks Installation Instructions for IDH Max 1300 Mortise Locks Components checklist Special tools checklist ❑ Field wiring for power connections between the lock Use the following checklist to make sure that you have the and power supply or the lock and access control panel.
  • Page 4: Preparing The Door And Door Jamb

    Installation Instructions for IDH Max 1300 Mortise Locks Preparing the door and door jamb Vert. centerline Mark centerlines of lock Note: If the door is a fabricated hollow metal door, determine whether it is properly reinforced to support the lock. If door reinforcement is not adequate, consult the door manufacturer for information on proper rein- forcement.
  • Page 5 Installation Instructions for IDH Max 1300 Mortise Locks Installation Instructions for IDH Max 1300 Mortise Locks Preparing the door and door jamb Mortise for lock case and faceplate Lock faceplate mortise 1 Mortise the edge of the door for the lock case.
  • Page 6 Field harness & reader wire hole door. Through-bolt Note 2: For holes through the door, it is best to drill half- holes way from each side of the door to prevent the door from splintering. Cylinder...
  • Page 7 Installation Instructions for IDH Max 1300 Mortise Locks Installation Instructions for IDH Max 1300 Mortise Locks Preparing the door and door jamb Drill hole for field wire harness Caution 1: Check with your local fire marshal Hinge mortise before drilling a fire-rated door. Drilling through a fire-rated door may void the fire label.
  • Page 8: Installing The Lock

    Installation Instructions for IDH Max 1300 Mortise Locks Installing the lock Mortise for strike box and strike plate 1 On the door jamb, locate the horizontal centerline of the strike (3/8″ above the centerline of the lock), as well as the vertical centerline of the strike.
  • Page 9 Installation Instructions for IDH Max 1300 Mortise Locks Installation Instructions for IDH Max 1300 Mortise Locks Installing the lock Mortise cavity Install mortise case Field wire harness 1 Remove the faceplate from the mortise case. 2 Insert the mortise case into the mortise cavity, while Sensor &...
  • Page 10 Installation Instructions for IDH Max 1300 Mortise Locks Installing the lock Install cylinder and mortise case face- plate Note: Install the cylinder for EEL and EEU function locks only. Case set screw 1 Thread the concealed cylinder into the mortise case so...
  • Page 11 Installation Instructions for IDH Max 1300 Mortise Locks Installation Instructions for IDH Max 1300 Mortise Locks Installing the lock Install trim hole inserts and bushings 1 Insert the two trim hole inserts into the upper trim hole on each side of the door, as shown in Figure 12.
  • Page 12 Installation Instructions for IDH Max 1300 Mortise Locks Installing the lock Caution 1: When routing the reader wire harness, Connect reader wire harness make sure the reader wire harness is not routed across any sharp edges or over any surface that could 1 From the outside of the door, feed the reader wire har- damage its sleeving or wire insulation.
  • Page 13 Installation Instructions for IDH Max 1300 Mortise Locks Installation Instructions for IDH Max 1300 Mortise Locks Installing the lock Set the control electronics board DIP switches Each IDH Max unit must be addressable (able to be identi- fied automatically by the access control system) with a unique address that matches its Lenel or B.A.S.I.S.®...
  • Page 14 Installation Instructions for IDH Max 1300 Mortise Locks Installing the lock For example, to address an IDH Max Lock with address number 5, the binary equivalent number would be 00101 – OFF OFF ON OFF ON. See table below. (16)
  • Page 15: Completing The Installation At The Door

    Installation Instructions for IDH Max 1300 Mortise Locks Installation Instructions for IDH Max 1300 Mortise Locks Completing the installation at the door Secure through-bolt trim and complete connections 1 Position the inside and outside trim onto the door. Inside trim 2 Making sure that the trim does not pinch the wires, secure the trim to the door—but do not...
  • Page 16 Installation Instructions for IDH Max 1300 Mortise Locks Completing the installation at the door 2 Slide the inside knob onto the inside spindle and secure it with the set screw. 3 Push the set screw cap into the set screw hole.
  • Page 17 Installation Instructions for IDH Max 1300 Mortise Locks Installation Instructions for IDH Max 1300 Mortise Locks Completing the installation at the door Install access door 1 Making sure that the access door does not pinch any wires, insert the tabs of the access door into its mating slots and swing the door closed.
  • Page 18 Installation Instructions for IDH Max 1300 Mortise Locks Completing the installation at the door Install strike box and strike plate 1 Insert the strike box into the mortise in the door jamb. Place the strike plate over the strike box and secure the strike with the screws provided.
  • Page 19: Testing The Installation

    Installation Instructions for IDH Max 1300 Mortise Locks Installation Instructions for IDH Max 1300 Mortise Locks Testing the installation Make Connect to the BAS-500 or BAS-1000 connections access control panel to the TR2+ TR2– and 1 If necessary daisy-chain all IDH Max Locks by splicing like wires and make all necessary wire runs to either a connectors.
  • Page 20: Troubleshooting The Installation

    Installation Instructions for IDH Max 1300 Mortise Locks Troubleshooting the installation Confirm that the red reader LED, green reader LED, and 7 With the door armed, hold the door open. Hold a mag- net against the edge of the door, over the door status sounder respond as expected.