Testing the installation

22
Connect to the BAS-500 or BAS-1000
access control panel
1 If necessary daisy-chain all IDH Max Locks by splicing
like wires and make all necessary wire runs to either a
BAS-500 or BAS-1000 panel.
Note: A BAS-500 panel will accept up to 16 IDH Max
1300 locks and a BAS-1000 panel will accept up to
32 IDH Max 1300 locks.
2 Connect the orange wire or its extension to the RS485
connection TR2+ or higher. See Figure 22.
3 Connect the green wire or its extension to the RS485
connection TR2– or higher.
4 Connect the shield strand to the RS485 connection
GND (ground).
23
Test the installation
After downloading the panel information to the IDH Max
Locks, perform the following steps to test the installation.
Also, perform any standard testing recommended by the
manufacturer of the access control panel. If you encounter
problems, see Troubleshooting the installation, on
page 20.
1 Check the control electronics' red status LED.
Both LEDs should be blinking red, indicating that the
communication connection between the access con-
trol panel and the lock's control electronics circuit
board is OK.
2 After performing any necessary programming for the
lock and putting the door in a locked mode, use a valid
token to access the lock.
Confirm that the red reader LED, green reader LED, and
sounder respond as expected.
The lock should allow access, verifying that the sole-
noid is working.
To check that the reader is working, view the lock's
event history and verify that the information recorded
for the token is correct.
3 Use an invalid token to attempt to access the lock.
Installation Instructions for IDH Max 1300 Mortise Locks
Installation Instructions for IDH Max 1300 Mortise Locks
LITHIUM
ION 3V
BR2325
J7
Figure 22 Making connections to the access control
BEST ACCESS SYSTEMS
A Division of Stanley Security Solutions, Inc
J8
J7
J1
5
J1
A
B
C
J1
6
J1
7
J1
8
U1
5
2
MEG
U1
U1
7
6
TR2 +
TR2 –
GND
J1
TR3 +
5
TR3 –
GND
J1
TR4 +
6
TR4 –
GND
TR5 +
J1
7
TR5 –
GND
J1
panel, BAS-1000 shown.
Make
connections
to the TR2+
TR2– and
TR2
+
GND
TR2
-
GN
D
connectors.
TR3
+
TR3
-
GN
D
TR4
+
TR4
-
GN
D
TR5
+
TR5
-
GN
D
S
1
J5
19

Hide quick links:

Advertisement

loading