Mortise locks

Advertisement

Preparing the door and door jamb
5
Drill hole for field wire harness
Caution 1: Check with your local fire marshal
before drilling a fire-rated door. Drilling through
a fire-rated door may void the fire label.
Caution 2: Be careful to drill straight through the
door, making sure the drill does not break
through the face of the door.
1 Remove the hinge nearest to the mortise cavity.
2 Using a three (3) to four (4) foot drill bit, drill a 3/8"
diameter hole through the upper back of the mortise
cavity to the center of the nearest hinge mortise.
Note: It may be easier to drill halfway from each side of
the door.
6
Prepare for wire transfer hinge and run
field wiring
1 Drill a wire access hole through the frame side of the
hinge mortise.
2 Drill holes (or pockets) for splice connectors in the
frame and door. Refer to the hinge manufacturer's
specifications for the hole location.
3 De-burr the holes to prevent damage to the hinge
leads.
4 Run the power field wiring from the location for the
lock's power supply to the location for the wire trans-
fer hinge.
5 Run the communication field wiring from the location
for the panel interface module to the location for the
wire transfer hinge.
Note: For an overview of the system, see the figure on
page 1. For specifications for power and communication
field wiring, see Components checklist, on page 2.
6 Pull the field wiring down the wall and through the
access hole in the frame.
Installation Instructions for IDH Max 1300 Mortise Locks
Installation Instructions for IDH Max 1300 Mortise Locks
Hinge mortise
Hole through
door
Upper back of
mortise cavity
Figure 5
Field wiring
(2 power &
2 communication)
Door frame
Figure 6
BEST ACCESS SYSTEMS
A Division of Stanley Security Solutions, Inc
Drilling the hole for the field wire harness
Preparing for the wire transfer hinge
Inside of door
Holes for splice
connectors