Please refer to the following sheet for detailed information.
Parameter Function
Protocol
Baud Rate
Data Bit
Stop bit
Parity

4.8.5.4 PTZ

The PTZ interface is shown as in Figure 4-92 (local type) and Figure 4-93 (remote type).
Before setup, please check the following connections are right:
PTZ and decoder connection is right. Decoder address setup is right.
Decoder A (B) line connects with DVR A (B) line.
Click Save button after you complete setup, you can go back to the monitor interface to control speed
dome.
Figure 4-91
Select the corresponding dome protocol.
Default setup is console.
Select the baud rate.
Default setup is 115200.
The value ranges from 5 to 8.
Default setup is 8.
There are two options: 1/2.
Default setup is 1.
There are five options: none/odd/even/space/mark.
Default setup is none.
Figure 4-92
188