Max Gain Adjustment; Auto White Balance & Lv Standard Data Input; Auto White Balance Adjustment - Sony DCR-TRV16 Service Manual

Digital video camera recorder
Table of Contents

Advertisement

DCR-TRV16/TRV16E/TRV18/TRV18E/TRV116E/TRV118E

9. MAX GAIN Adjustment

Setting the minimum illumination.
If it is not consistent, the image level required for taking subjects in
low illuminance will not be produced (dark).
Subject
Adjustment Page
Adjustment Address
Note1: The data of page: 0, address: 10 must be "00".
Note2: Check that the data of page: 6, address: 02 is "00". If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1) POWER .................................................................. CAMERA
2) NIGHT SHOT .................................................................. OFF
3) DIGITAL ZOOM (Menu display) ................................... OFF
4) STEADY SHOT (Menu display) ..................................... OFF
Adjusting method:
Order Page Address Data
1
0
01
2
6
48
3
6
96
4
6
97
5
6
01
6
6
02
Note3: The adjustment data will be automatically input to page: F, address:
1D.
Processing after Completing Adjustments
Order Page Address Data
1
6
48
2
6
96
3
6
97
4
6
01
5
0
01
Clear chart
(Color reproduction adjustment frame)
F
1D
Procedure
01
Set the data.
01
Set the data.
27
Set the data.
00
Set the data.
6F
Set the data, and press PAUSE
button.
Check that the data changes to
"01". (Note3)
Procedure
00
Set the data.
00
Set the data.
00
Set the data.
00
Set the data, and press PAUSE
button.
00
Set the data.
10. Auto White Balance & LV Standard Data Input
Adjust the white balance reference at 3200K, and adjust the normal
coefficient of the light value.
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note1: This adjustments should be carried out upon completion of "Color
reproduction adjustment" and "MAX GAIN adjustment".
Note2: After the power is turned on, this adjustment can be done only
once.
Note3: The data of page: 0, address: 10 must be "00".
Note4: Check that the data of page: 6, address: 02 is "00". If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note5: Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Switch setting:
1) POWER .................................................................. CAMERA
2) NIGHT SHOT .................................................................. OFF
3) DIGITAL ZOOM (Menu display) ................................... OFF
4) STEADY SHOT (Menu display) ..................................... OFF
Adjusting method:
Order Page Address Data
1
0
01
2
6
48
3
4
6
01
5
6
01
6
6
02
7
0
03
8
1
Note6: The adjustment data will be automatically input to page: F, address:
1E, 1F, 2A to 2D.
Processing after Completing Adjustments
Order Page Address Data
1
6
01
2
6
48
3
0
03
4
0
01
5
5-26
Clear chart
(Color reproduction adjustment frame)
Display data of page 1 (Note5)
Adjustment remote commander
F
1E, 1F, 2A to 2D
0FF0 to 1010
Display data
Procedure
01
Set the data.
01
Set the data.
Wait for 2 sec.
11
Set the data, and press PAUSE
button.
0D
Set the data, and press PAUSE
button.
Check that the data changes to
"01". (Note6)
1E
Set the data.
Check that the display data
(Note5) satisfies the specified
value.
Procedure
00
Set the data, and press PAUSE
button.
00
Set the data.
00
Set the data.
00
Set the data.
Perform "Auto White Balance