1-2.
INITIALIZATION OF 7, 8, C, D, E, F PAGE
DATA
1-2-1. INITIALIZATION OF 8, C, D PAGE DATA
1. Initializing the 8, C, D Page Data
Note1: If "Initialization of Pages 8, C, D" is executed, all data
on pages 8, C and D are initialized. (Only an individual
page cannot be initialized)
Note2: If the 8, C, D page data has been initialized, "Modifica-
tion of 8, C, D Page Data" and following adjustments
need to be performed again.
1) Electronic viewfinder system adjustment
2) LCD system adjustment
3) System control system adjustment
4) Servo and RF system adjustment
5) "S VIDEO OUT Y level adjustment" and "S VIDEO OUT
chroma level adjustment" of the video system adjustments.
Adjusting Page
Adjusting Address
Adjusting Page
Adjusting Address
Adjusting Page
Adjusting Address
Initializing Method:
Order Page Address Data
1
0
01
2
3
81
3
3
80
4
3
80
5
8
00 to FF
C
10 to FF
D
10 to FF
Procedure
01
10
0A
Press PAUSE button.
Check the data changes to
"1A".
Perform "Modification of 8,
C, D Page Data"
2. Modification of 8, C, D Page Data
If the 8, C, D page data has been initialized, change the data of the
"Fixed data-2" address shown in the following table by manual
input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the
camcorder may not operate.
3) When changing the data, press the PAUSE button of the ad-
justment remote commander each time when setting new data
to write the data in the non-volatile memory.
4) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of D Page data
Order Page Address Data
1
2
00
2
2
01
3
0
01
Note: If the following symptoms occur after completing of the
"Modification of D page data", check that the data of the
"Fixed data-2" addresses of D page are same as those of
the same model of the same destination.
1) "E: 20 : 00" of self-diagnosis code on the LCD screen
is flashing.
2) The power is shut off so that unit cannot operate.

3. 8 Page Table

Note1: Fixed data-1: Initialized data. (Refer to "1. Initializing
the 8, C, D Page Data")
Note2: Fixed data-2: Modified data. (Refer to "2. Modification
of 8, C, D Page Data")
Initial value
Address
NTSC PAL
00 to 6E
6F
70 to 8F
90
91 to FF
5-8
Procedure
29
29
Press PAUSE button.
00
Remark
Fixed data-1 (Initialized data)
Fixed data-2
Fixed data-1 (Initialized data)
Fixed data-2
Fixed data-1 (Initialized data)

Hide quick links: