Indoor Unit
1.3

Removal of Horizontal Blade and Vertical Blade

Procedure
Step
1. Remove
horizontal
blade.
Lift horizontal blade to
1
open position.
Disengage horizontal
2
blade from blade
retaining section.
Bend blade slightly and
3
remove it from the unit.
140
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
SiBE04-401
Points
Screw stoppers inside the
flap which were equipped in
the existing models are not
provided.