Removal Of Horizontal Blade - Daikin FLKS25BAVMB Service Manual

Removal procedure 2.5/3.5/5.0/6.0 kw class, indoor unit, inverter, floor/ceiling suspended dual type, cooling only, heat pump
Hide thumbs Also See for FLKS25BAVMB:
Table of Contents

Advertisement

Si051060

3. Removal of Horizontal Blade

Procedure
Step
Open the horizontal
1
blade.
2
Deflect the 3 center
bearings to the left side
slightly, and release the
shafts of the horizontal
blade.
3
Bend the horizontal
blade slightly to release
the shafts from
bearings at the both
ends. (Release the left
side shaft first.)
Removal Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
(1)
Horizontal blade
(R2993)
(2)
Removal of Horizontal Blade
Points
(R14198)
7