Appendix 1 - Main Parameters - Kane 450 User Manual

Flue gas analyser
Table of Contents

Advertisement

Appendix 1 - Main Parameter:
Here are the legends used and what they mean:
O
:
Oxygen reading in percentage (%)
2
O2R:
Oxygen reference setting. '----' means switched off or set to 0%.
T Flue:
Temperature measured by the flue gas probe in Centigrade or Fahrenheit. It
displays '- OC -' if the flue probe is disconnected.
T Nett :
Nett temperature calculated by deducting the AMBIENT or INLET
temperature from the measured FLUE temperature. Displays in either
Fahrenheit (°F) or Centigrade (°C) or and will display '- OC -' if the flue
probe is not connected.
T inlet:
Temperature measured by the inlet temperature probe in Centigrade or
Fahrenheit. It displays '- OC -' if the flue probe is disconnected.
CO:
Carbon Monoxide reading displayed in ppm (parts per million). '- - -' is
displayed if there is a fault with the CO sensor or the instrument has not set
to zero correctly, switch off instrument and try again.
C0m:
Carbon Monoxide displayed in mg/m
COn:
Carbon Monoxide in ppm normalised to the O2R value
COĦ:
Carbon Monoxide in mg/m3 normalised to the O2R value.
COa
Carbon Monoxide calculation as if there were 0% Oxygen present. This is
only displayed in ppm
CO
:
Carbon Dioxide calculation determined by fuel type. This is only displayed
2
when a combustion test is being carried out. '-O>-' is displayed while in
fresh air.
EFF :
Combustion efficiency calculation displayed in percentage either as Gross
(G) or Nett (N) or Condensing Nett (C) - Use MENU to change. The
calculation is determined by fuel type and uses the calculation in British
Standard BS845. The efficiency is displayed during a combustion test, '-
O>-' is displayed while in fresh air.
X - AIR :
Excess air calculated from the measured oxygen and type of fuel used.
Displays reading during a combustion test. '-O>-' is displayed while in
fresh air.
Loss :
Losses calculated from Oxygen and type of fuel. Displays reading during a
combustion test. '-O>-' is displayed while in fresh air.
Supplied By www.heating spares.co Tel. 0161 620 6677
3
.
KANE450 manual
Page 29

Advertisement

Table of Contents
loading

Table of Contents