12.0 TROUBLESHOOTING

12.1 Electronic Ignition System

ATTENTION: Troubleshooting must be performed by a qualified
technician.
Before proceeding with the steps in the following troubleshooting
guide,
Verify proper 120VAC power supply to the control module.
Verify the control module battery pack are fresh and installed
Issue
Pilot will not light
Pilot will not stay lit
Pilot flame always on, or
will not extinguish
Main burner flame will not
light
Cause
Electrical power interrupted or
disconnected
Wiring disconnection
Gas supply turned off
No LP (propane) gas in tank
Low gas pressure
Pilot flame not making contact
with the flame rectification
sensor on the pilot assembly
Pilot adjustment screw not
sealed
Control system set to CPI mode
ON/OFF rocker switch in OFF
position
Gas supply turned off
Low gas supply
Wiring disconnection or
improper wiring
Plugged main burner orifice
Pilot flame
with correct polarity.
Verify all connections between the wire harnesses and the
system components are proper and positive.
Verify inlet pressure meets the recommended inlet pressure.
If necessary, adjust line pressure regulator.
Restore electrical power to appliance or use battery back-up.
Ensure batteries are fully charged if using battery back-up as
power source.
Use wiring schematic in this manual to determine that all wiring
connections are secure and correct.
Check remote shut-off valves from the appliance. Usually there is
a valve near the main gas line. There may be more than (1) valve
between the appliance and main gas line.
Check LP (propane tank). Refill if necessary.
Consult a plumber or a gas supplier.
Can be caused by situations such as a bent line, too narrow
diameter or pipe, or a low line pressure.
Verify the pilot flame envelopes the top of the flame sensor and
extends far enough onto burner for ignition.
To adjust pilot flame, turn pilot adjustment screw on the gas valve
clockwise to decrease flame, and counterclockwise to increase
flame.
Seal pilot adjustment screw. Do not over-tighten.
Set control system to IPI mode.
Switch rocker switch to ON position.
Check for multiple shut-offs in the supply line. Verify gas supply is
turned on.
Consult with plumber or gas supplier.
Check LP (propane) tank. Refill if necessary.
Check for faulty or incorrect wiring.
Remove blockage.
Verify the pilot flame is properly directed to ignite burner. See pilot
flame troubleshooting above.
Solution
TROUBLESHOOTING 41