7.7 #700-2 Series Direct Vent
Termination Kit(s)
IMPORTANT: The vertical vent heat shield included with this
fireplace must be installed for every type of venting application.
IMPORTANT: The flex pipe is permanently attached to the
exterior plate. DO NOT ATTACH either #745-2 or #718-2
termination kit to fireplace (or extension kit) until it has passed
through the wall. Install termination plates to the outside wall
exterior.
IMPORTANT: The minimum bend radius to center is 6 in (152
mm) required for installation of the flexible vent pipe. Care
should be taken when installing the flexible vent pipe to avoid
a tight bend that may cause abrasion or damage to the flexible
pipe.
If terminating against vinyl siding, a vinyl siding protector
must be used (included with the #745-2 and #718-2 direct
vent kits). Follow instructions included.
Each #746-2 extension kit contains enough 4" & 7" flexible
aluminum pipe to extend chimney an additional 6 ft (1.83 m).
7.7.1 Assembly and Installation
1.
Mount the required wall thimble (G) with 1 in (25 mm) top
clearance and 1 in (25 mm) side clearance to the exterior
#700-WPT
G
Figure 7.3, Installation and Assembly of #700-2 Series (Vent Heat Shield Assembly not shown for clarity purposes only)
wall, and seal.
(OPTIONAL) insulate the wall thimble with any unfaced
insulation products listed as non-combustible per ASTM E
136.
2.
Apply a liberal bead of exterior sealant around outer edge of
termination box (A), placing assembly through the wall-pass
through in exterior wall. Place screws through the four holes
(B), securing it in place.
3.
Form the 4" & 7" flexible aluminum pipes on termination kit
(#745-2 or #718-2), and if applicable, on each extension kit.
4.
Gently pull 4" & 7" pipes down to the top of the fireplace, or if
applicable, the extension kit.
IMPORTANT: DO NOT stretch extension kit beyond 6 ft.
(1.83 m); DO NOT stretch beyond what is required. It is
very difficult to decompress flex pipes once stretched.
5.
Place a bead of sealant outside 4" flex pipe collar (C) (end
with EXTERNAL LIP) and sliding it into 4" pipe on extension
kit or top of fireplace (D). Secure with 3 evenly spaced
screws.
6.
Place a bead of sealant inside 7" flex pipe collar (E) (end
with the INTERNAL lip), sliding it over 7" pipe on top of
fireplace (F). Secure with 3 evenly spaced screws.
7.
If additional extension kits are required, repeat Steps 4 and
5, placing 4" & 7" pipes onto previous extension kit.
A
B
E
C
D
F
LEGEND
A
Termination box
B
Holes in exterior wall plate (only 3 shown)
C
4" flex pipe collar
D
4" pipe on fireplace or extension kit
E
7" flex pipe collar
F
7" pipe on fireplace or extension kit
G
Wall Thimble with 1 in (25 mm) top clearance
VENTING 25