2. GENERAL SPECIFICATIONS

This section provides specifications common to the relevant modules.
Item
Operating ambient
temperature
Température
ambiante de
fonctionnement
Storage ambient
temperature
Operating ambient
humidity
Storage ambient
humidity
Vibration
resistance
Shock resistance
Operating
atmosphere
Operating
*1
altitude
Installation
location
Overvoltage
*2
category
*3
Pollution degree
Equipment
category
*1 Do not use or store the head module under pressure higher than the atmospheric pressure
at an altitude of 0m. Doing so can cause a malfunction.
To use it in a pressurized environment, please contact your local Mitsubishi representative.
Compliant
Under
with JIS B
intermittent
3502 and
vibration
IEC
61131-2
Under
continuous
vibration
Compliant with JIS B 3502 and IEC 61131-2
(147m/s
Specifications
0 to 55°C
0 à 55 °C
-25 to 75°C
5 to 95%RH, non-condensing
Constant
Frequency
acceleration
5 to 8.4Hz
8.4 to
9.8m/s
150Hz
5 to 8.4Hz
8.4 to
4.9m/s
150Hz
2
,3 times each in X, Y, and Z directions)
No corrosive gases
0 to 2000m
Inside control panel
II or lower
2 or lower
Class I
31
Half
amplitude
3.5mm
2
1.75mm
2
Sweep
count
10 times
each in
X,Y, and
Z
directions