Supermicro SUPERSERVER 2028TP-HTR-SIOM User Manual page 79

Table of Contents

Advertisement

SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL
Appendix B: System Specifications
Notes
Chassis
SC217HQ+-R2K04BP2 (2U rackmount)
Dimensions: (WxHxD) 17.25 x 3.47 x 28.5 in. (438 x 88 x 724 mm)
Weight
Gross (Bare Bone): 88 lbs. (40 kg.)
System Cooling
The system has four 8-cm PWM system cooling fans
System Input Requirements
AC Input Voltage: 100-240V AC auto-rangeRated Input Current: 16-12A (110-
140V), 12.5-9.5A (180-240V)
Rated Input Frequency: 50 to 60 Hz
Efficiency: 80+ (Platinum Level)
Power Supply
Rated Output Power: 2000W (Part# PWS-2K04A-1R) (redundant, hot-plug)
Rated Output Voltages: +12V (167A), +5Vsb (1A)
Operating Environment
Operating Temperature: 0º to 35º C (32º to 95º F)
Non-operating Temperature: -40º to 70º C (-40º to 158º F)
Operating Relative Humidity: 20% to 95% (non-condensing)
Non-operating Relative Humidity: 5 to 95% (non-condensing)
Regulatory Compliance
Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-
3, CISPR 22 Class A
Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3,
EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11)
Safety: CSA/EN/IEC/UL 60950-1 Compliant, UL or CSA Listed (USA and
Canada), CE Marking (Europe)
California Best Management Practices Regulations for Perchlorate Materials:
This Perchlorate warning applies only to products containing CR (Manganese
Dioxide) Lithium coin cells. "Perchlorate Material-special handling may apply.
See www.dtsc.ca.gov/hazardouswaste/perchlorate" for further details.