Table of Contents

Advertisement

Quick Links

SUPERSERVER
®
2028TP-HTR-SIOM
2028TP-HC0R-SIOM
2028TP-HC1R-SIOM
USER'S MANUAL
Revision 1.0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SUPERSERVER 2028TP-HTR-SIOM and is the answer not in the manual?

Questions and answers

Summary of Contents for Supermicro SUPERSERVER 2028TP-HTR-SIOM

  • Page 1 SUPERSERVER ® 2028TP-HTR-SIOM 2028TP-HC0R-SIOM 2028TP-HC1R-SIOM USER'S MANUAL Revision 1.0...
  • Page 2 This product, including software and This manual is written for professional system integrators and PC technicians. documentation, is the property of Supermicro and/or its licensors, and is supplied only under a It provides information for the installation and use of the SuperServer license.
  • Page 3 SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Notes Chapter 6: Advanced Chassis Setup Refer to Chapter 6 for detailed information on the SC217HQ+-R2K04BP2 server chassis. You should follow the procedures given in this chapter when installing, removing or reconfiguring hard drives and when replacing system power supply units and cooling fans.
  • Page 4: Table Of Contents

    About Standardized Warning Statements ............4-1 Air Shrouds ..................... 1-4 Warning Definition ................... 4-1 Mounting Rails ....................1-4 Installation Instructions ..................4-4 Contacting Supermicro ..................1-6 Circuit Breaker ....................4-5 2U Twin : System Notes ................. 1-7 Power Disconnection Warning ................ 4-6 Nodes ......................
  • Page 5 SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Table of Contents Chapter 7 BIOS Installing Memory .................... 5-9 Memory Support ....................5-9 Introduction ...................... 7-1 Memory Support for E5-2600 (v3)-based Serverboards ......5-10 Starting BIOS Setup Utility ................7-1 Memory Support for E5-2600 (v4)-based Serverboards ......5-11 How To Change the Configuration Data ............
  • Page 6: Superserver 2028Tp-Htr/Hc0R/Hc1R-Siom User's Manual

    SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Notes...
  • Page 7: Chapter 1 Introduction

    X10DRT-PS dual processor serverboard, which reside in four hot-swap nodes. Please refer to our website for information on operating systems that have been certified for use with the system (www.supermicro.com). In addition to the serverboard and chassis, various hardware components have...
  • Page 8: Serverboard Features

    In addition, the 2028TP-HTR/HC0R/HC1R-SIOM was designed to accept one of four processors (Socket R LGA 2011). Please refer to the serverboard description pages different SIOM modules (Supermicro I/O Module) to satisfy the specific I/O functions on our web site for a complete listing of supported processors (www.supermicro.
  • Page 9: Server Chassis Features

    SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 1: Introduction Server Chassis Features The following is a general outline of the main features of the SC217HQ+ server Figure 1-1. Intel PCH C612 Chipset: chassis. System Block Diagram Note: This is a general block diagram and may not exactly repre- System Power sent the features on your serverboard.
  • Page 10: Contacting Supermicro

    +1 (408) 503-8008 nodes, each may be powered off and on without affecting the others. In addition, Email: marketing@supermicro.com (General Information) each node is a hot-swappable unit that may be removed from the rear of the chassis. support@supermicro.com (Technical Support) The nodes are connected to the server backplane by means of an adapter card.
  • Page 11 SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Notes...
  • Page 12: Chapter 2 Server Installation

    Chapter 2: Server Installation Chapter 2 Server Installation Overview This chapter provides a quick setup checklist to get your SuperServer 2028TP-HTR/HC0R/HC1R-SIOM up and running. Following these steps in the order given should enable you to have the system operational within a minimum amount of time.
  • Page 13: Choosing A Setup Location

    SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 2: Server Installation Choosing a Setup Location Rack Mounting Considerations • Leave enough clearance in front of the rack to enable you to open the front door completely (~25 inches) and approximately 30 inches of clearance in the back Ambient Operating Temperature of the rack to allow for sufficient airflow and ease in servicing.
  • Page 14: Installing The System Into A Rack

    SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 2: Server Installation Installing the System into a Rack Locking Tabs Each inner rail has a locking tab. This tab locks the chassis into place when installed This section provides information on installing the 2028TP-HTR/HC0R/HC1R-SIOM and pushed fully into the rack.
  • Page 15: Installing The Inner Rails On The Chassis

    SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 2: Server Installation Installing The Inner Rails on the Chassis Installing the Outer Rails on the Rack To install the inner rails, use the procedure below. Use the procedure below to install the outer rails onto the rack. Installing the Inner Rails (Figures 2-3 and 2-4) Installing the Outer Rails (Figure 2-5) 1.
  • Page 16: Standard Chassis Installation

    SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Standard Chassis Installation Installing the Chassis into a Rack (Figure 2-6) 1. Confirm that the inner rails are properly installed on the chassis. 2. Confirm that the outer rails are correctly installed on the rack. 3. Pull the middle rail out from the front of the outer rail and make sure that the ball-bearing shuttle is at the front locking position of the middle rail.
  • Page 17: Chapter 3 System Interface

    Chapter 3: System Interface Chapter 3 System Interface Overview There are several LEDs on the control panel and on the drive carriers to keep you constantly informed of the overall status of the system. SC217HQ+ models include four front panels on the handles of the chassis which control each of the systems. This chapter explains the meanings of all LED indicators and the appropriate response you may need to take.
  • Page 18: Control Panel Button

    SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 3: System Interface • Control Panel Button A flashing red light which flashes in four second interfals indicates a power failure. When notified of an alert, check the routing of the cables and make sure all fans are present and operating normally.
  • Page 19 SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Notes...
  • Page 20: Chapter 4 Standardized Warning Statements For Ac Systems

    Only certified technicians should attempt to install or configure components. Read this appendix in its entirety before installing or configuring components in the Supermicro chassis. These warnings may also be found on our web site at http://www.supermicro.com/ about/policies/safety_information.cfm. Warning Definition Warning! This warning symbol means danger.
  • Page 21 SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Warning Statements for AC Systems ‫جسذٌة‬ ‫اصابة‬ ً‫تتسبب ف‬ ‫حالة ٌوكي أى‬ ً‫اًك ف‬ ‫خطز‬ ًٌ‫ٌع‬ ‫هذا الزهز‬ !‫تحذٌز‬ Warnung ‫الذوائز‬ ‫بالوخاطز الٌاجوة عي‬ ‫ي على علن‬ ، ‫ك‬ ‫هعذات‬ ‫تعول على أي‬ ‫قبل أى‬ ‫الكهزبائٍة‬ WICHTIGE SICHERHEITSHINWEISE ‫حىادث‬...
  • Page 22: Installation Instructions

    SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 4: Warning Statements for AC Systems Installation Instructions Circuit Breaker Warning! Warning! Read the installation instructions before connecting the system to the power source. This product relies on the building's installation for short-circuit (overcurrent) 設置手順書 protection.
  • Page 23: Power Disconnection Warning

    SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 4: Warning Statements for AC Systems Warnung Das System muss von allen Quellen der Energie und vom Netzanschlusskabel ‫في‬ ‫التي تم تثبيتها‬ ‫مه الدوائرالقصيرة‬ ‫الحمايت‬ ‫معداث‬ ‫يعتمد على‬ ‫هذا المنتج‬ getrennt sein, das von den Spg.Versorgungsteilmodulen entfernt wird, bevor es ‫المبنى‬...
  • Page 24: Equipment Installation

    SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 4: Warning Statements for AC Systems Equipment Installation Waarschuwing Deze apparatuur mag alleen worden geïnstalleerd, vervangen of hersteld door geschoold en gekwalificeerd personeel. Warning! Only trained and qualified personnel should be allowed to install, replace, or service Restricted Area this equipment.
  • Page 25: Battery Handling

    SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 4: Warning Statements for AC Systems Warnung ‫אזור עם גישה מוגבלת‬ Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die !‫אזהרה‬ Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp. ‫יש להתקין את היחידה באזורים שיש בהם הגבלת גישה. הגישה ניתנת בעזרת‬ Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers.
  • Page 26: Redundant Power Supplies

    SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 4: Warning Statements for AC Systems Redundant Power Supplies ‫امداد الطاقة‬ ‫بوحدات‬ ‫عدة اتصاالت‬ ‫جهاز‬ ‫ال‬ ‫يكون لهذا‬ ‫قد‬ ‫الكهرباء‬ ‫عن‬ ‫وحدة‬ ‫ال‬ ‫لعسل‬ ‫كافة االتصاالت‬ ‫يجب إزالة‬ Warning! This unit might have more than one power supply connection. All connections must 경고! be removed to de-energize the unit.
  • Page 27: Comply With Local And National Electrical Codes

    SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 4: Warning Statements for AC Systems Attention ¡Advertencia! Lorsque le système est en fonctionnement, des tensions électriques circulent sur La instalacion del equipo debe cumplir con las normas de electricidad locales y le fond de panier. Prendre des précautions lors de la maintenance. nacionales.Attention L'équipement doit être installé...
  • Page 28: Hot Swap Fan Warning

    SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 4: Warning Statements for AC Systems 当您从机架移除风扇装置,风扇可能仍在转动。小心不要将手指、螺丝起子和其他 Warnung 物品太靠近风扇 Die Entsorgung dieses Produkts sollte gemäß allen Bestimmungen und Gesetzen des Landes erfolgen. 警告 ¡Advertencia! 當您從機架移除風扇裝置,風扇可能仍在轉動。小心不要將手指、螺絲起子和其他 物品太靠近風扇。 Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales.
  • Page 29: Power Cable And Ac Adapter

    UL ou CSA câbles certifiés qui ont UL ou CSA indiqué sur le code use of UL or CSA -certified cables (that have UL/CSA shown on the code) for any pour tous les autres appareils électriques que les produits désignés par Supermicro other electrical devices than products designated by Supermicro only.
  • Page 30 Elektrisch apparaat en veiligheidsinformatiebladen wet verbiedt het gebruik van UL of CSA gecertificeerde kabels die UL of CSA die op de code voor andere elektrische apparaten dan de producten die door Supermicro alleen. 4-20...
  • Page 31: Chapter 5 Advanced Serverboard Setup

    Chapter 5: Advanced Serverboard Setup Chapter 5 Advanced Serverboard Setup This chapter covers the steps required to connect data and power cables and install add-on cards. All serverboard jumpers and connections are also described. A layout and quick reference chart are included in this chapter for your reference. Remember to completely close the chassis when you have finished working with the serverboard to better cool and protect the system.
  • Page 32: Connecting Cables

    SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 5: Advanced Serverboard Setup Connecting Cables Rear I/O Ports Now that the processors are installed, the next step is to connect the cables to See Figure 5-1 below for the and locations of the various rear I/O ports and the the serverboard.
  • Page 33: Processor And Heatsink Installation

    • Install the processor into the CPU socket before installing the heatsink. • plate with your fingers to open it Refer to the Supermicro web site for updates on CPU support. completely. IMPORTANT! 4. Pop the plastic cap marked "Warning" out of the load plate.
  • Page 34: Installing A Passive Cpu Heatsink

    SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 5: Advanced Serverboard Setup Installing a Passive CPU Heatsink Gently close 1. Do not apply any thermal grease to the heatsink or the CPU die -- the the load plate. 7. With the "Close 1st" lever fully required amount has already been applied.
  • Page 35: Removing The Heatsink

    The X10DRT-PS has sixteen DIMM slots supporting up to 2 TB of LRDIMM (Load Screw#3 Reduced DIMM) or 1 TB of RDIMM (Registered DIMM) DDR4-2400/2133/1866 MHz Screw#2 registered ECC memory. Note: Check the Supermicro website (www.supermicro.com) for the latest memory support information. Figure 5-2. DIMM Installation Screw#4 Release Tab...
  • Page 36: Memory Support For E5-2600 (V3)-Based Serverboards

    SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 5: Advanced Serverboard Setup Processor & Memory Module Population Configuration Memory Support for E5-2600 (v4)-based Serverboards For memory to work properly, follow the tables below for memory installation. Speed (MT/s); Voltage (V); Slot Per Channel (SPC) and DIMM Per Channel (DPC) Processors and their Corresponding Memory Modules DIMM Capacity...
  • Page 37: Serverboard Details

    SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 5: Advanced Serverboard Setup Serverboard Details X10DRT-PS Quick Reference Jumper Description Default Setting Figure 5-3. X10DRT-PS Serverboard Layout (not drawn to scale) JBT1 Clear CMOS See Section 5-9 JPB1 BMC Enable/Disable Pins 1-2 (Enabled) UID_LED1 JPG1 VGA Enable/Disable Pins 1-2 (Enabled)
  • Page 38: Connector Definitions

    SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 5: Advanced Serverboard Setup Connector Definitions Video Port A Video (VGA) port is located on the rear I/O panel. The VGA port is supported by Main Power the ASpeed BMC and is used to provide video and CRT display. Main power to the serverboard is supplied through the system backplane (BPN- SAS3-217HQ), which receives power directly from the power supply.
  • Page 39: Jumper Settings

    SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 5: Advanced Serverboard Setup Jumper Settings Watch Dog Enable/Disable Connector Watch Dog (JWD1) is a system monitor Pins that can reboot the system when a Watch Dog Explanation of Jumpers Jumper Settings software application hangs. Close pins Jumper Setting Definition To modify the operation of the serverboard,...
  • Page 40: 5-10 Onboard Indicators

    SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 5: Advanced Serverboard Setup 5-10 Onboard Indicators BMC Heartbeat LED BMC Heartbeat LED (LEM1) LAN 1/LAN 2 Status A BMC Heartbeat LED is provided to Color/State Definition display BMC status. When blinking, IPMI LAN Green: Blinking BMC:Normal BMC is functioning normally.
  • Page 41: 5-11 Pci-Express And Sata Connections

    Chapter 5: Advanced Serverboard Setup 5-11 PCI-Express and SATA Connections 5-12 Installing Software The Supermicro FTP site contains drivers and utilities for your system at ftp://ftp. S-SATA 0-2/CPU2_PCI-Express 3.0 x16 Slot (SXB1) supermicro.com. Some of these must be installed, such as the chipset driver.
  • Page 42: Superdoctor® 5

    5-13 Onboard Battery SuperDoctor® 5 The Supermicro SuperDoctor 5 is a program that functions in a command-line Please handle used batteries carefully. Do not damage the battery in any way; a or web-based interface in Windows and Linux operating systems. The program damaged battery may release hazardous materials into the environment.
  • Page 43 SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Notes 5-24...
  • Page 44: Chapter 6 Advanced Chassis Setup

    Chapter 6: Advanced Chassis Setup Chapter 6 Advanced Chassis Setup This chapter covers the steps required to install components and perform maintenance on the SC217HQ+-R2K04BP2 chassis. For component installation, follow the steps in the order given to eliminate the most common problems encountered.
  • Page 45: Control Panel

    SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 6: Advanced Chassis Setup Chassis Cover Figure 6-1. Front and Rear Chassis Views Control Panel Control Panel Before operating the SC217HQ+ chassis for the first time, it is important to remove the protective film covering the top of the chassis, in order to allow for proper ventilation and cooling.
  • Page 46: Air Shrouds

    SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 6: Advanced Chassis Setup Air Shrouds Checking the Airflow Air shrouds concentrate airflow to maximize fan efficiency. The SC217HQ+ chassis Checking Airflow requires air shrouds for each serverboard node. Air shrouds vary depending upon 1. Make sure there are no objects obstructing the airflow in and out of the the serverboard used.
  • Page 47 SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 6: Advanced Chassis Setup Changing a System Fan Figure 6-5. Replacing a System Fan in the Fan Housing 1. If necessary, open the chassis while the power is running to determine which fan has failed. (Never run the server for an extended period of time with the chassis cover open.) 2.
  • Page 48: Removing And Installing The Backplane

    SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 6: Advanced Chassis Setup Removing and Installing the Backplane 6. Loosen the three screws in the spring bar, located on the floor of the chassis, indicated by the arrows below (Figure 6-7). The SC217HQ+ chassis backplane is located behind the hard drives and in front Figure 6-7.
  • Page 49: Installing The Backplane

    SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 6: Advanced Chassis Setup Installing the Serverboard Installing the Backplane Installing the Backplane into the Chassis (Figure 6-9) 1. Ensure that all of the hard drive carriers have been removed from the bays in I/O Shield the front of the chassis and that the spring bar has been loosened as directed The I/O shield holds the serverboard ports in place.
  • Page 50 SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 6: Advanced Chassis Setup Figure 6-10. Removing Serverboard Node Drawer 9. Connect the cables between the serverboard, backplane, chassis, front panel, and power supply, as needed. Also, fans may be temporarily removed to allow access to the backplane ports. 10.
  • Page 51: Adapter Card Replacement

    SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 6: Advanced Chassis Setup Adapter Card Replacement Expansion Card/PCI Slot Setup The SC217HQ+ chassis supports one low-profile expansion PCI slot for each node, Each serverboard drawer comes equipped with an adapter card that plugs into the for a total of four PCI slots in the chassis.
  • Page 52: 6-10 Drive Bay Installation/Removal

    1" high, SATA drives in the system. 4. Remove the PCI PCI slot shield. Note: Refer to the following FTP site for setup guidelines: <ftp://ftp.supermicro.com/ 5. Place the expansion card into the serverboard node drawer. driver/SAS/LSI/LSI_SAS_EmbMRAID_SWUG.pdf> and Supermicro's web site for additional inmformation <...
  • Page 53 Cauton: Except for short periods of time while swapping hard drives, do not operate the server with the hard drives empty. Caution: Enterprise level hard disk drives are recommended for use in Supermicro chassis and servers. For information on recommended HDDs, visit the Supermicro website at http://www.supermicro.com/products/nfo/files/storage/SAS-CompList.pdf...
  • Page 54: 6-11 Power Supply

    Replacement units can be ordered directly from Supermicro (See the contact information in the Preface of this manual). Changing the Power Supply 1.
  • Page 55: Chapter 7 Bios

    When an option is selected in the left frame, it is highlighted in white. Often a text message will accompany it. Note: the AMI BIOS has default text messages built in. Supermicro retains the option to include, omit, or change any of these text messages.
  • Page 56: How To Start The Setup Utility

    Flashing the wrong BIOS can cause irreparable damage to the system. In no event shall as 17:30:00. Supermicro be liable for direct, indirect, special, incidental, or consequential damages arising from a BIOS update. If you have to update the BIOS, do not shut down or reset Supermicro X10DRT-P Series the system while the BIOS is updating to avoid possible boot failure.
  • Page 57: Advanced Setup Configurations

    SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 7: BIOS Advanced Setup Configurations Wait For 'F1' If Error Select Enabled to force the system to wait until the 'F1' key is pressed if an error Use the arrow keys to select Advanced setup and press <Enter> to access the occurs.
  • Page 58 SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 7: BIOS CPU Configuration  Hardware Prefetcher (Available when supported by the CPU) If set to Enable, the hardware prefetcher will prefetch streams of data and instruc- This submenu displays the following CPU information as detected by the BIOS. It tions from the main memory to the L2 cache to improve CPU performance.
  • Page 59: Advanced Power Management Configuration

    SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 7: BIOS X2 APIC (Advanced Programmable Interrupt Controller) P-state Coordination Based on Intel's Hyper-Threading architecture, each logical processor (thread) is This feature is used to change the P-state (Power-Performance State) coordi- assigned 256 APIC IDs (APIDs) in 8-bit bandwidth. When this feature is set to En- nation type.
  • Page 60: Chipset Configuration

    SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 7: BIOS Chipset Configuration IOU0 (II0 PCIe Port 2) This item configures the PCI-E port Bifuraction setting for a PCI-E port specified Warning! Please set the correct settings for the items below. A wrong configuration by the user.
  • Page 61 SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 7: BIOS  Intel VT for Directed I/O (VT-d) Link Speed Mode Use this item to select the data transfer speed for QPI Link connections. The Intel VT for Direct I/O (VT-d) options are Fast and Slow. Intel VT for Directed I/O (VT-d) ®...
  • Page 62: Dimm Information

    SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 7: BIOS Data Scrambling the same set of operations in parallel to boost performance. The options are Disable, Mirror, and Lockstep Mode. Select Enabled to enable data scrambling to enhance system performance and data integrity. The options are Auto, Disabled and Enabled. Lockstep x4 DIMMs DRAM RAPL (Running Average Power Limit) Baseline Select Enable to enable Lockstep support for x4 DIMM modules.
  • Page 63: South Bridge

    SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 7: BIOS South Bridge EHCI2  Select Enabled to enable EHCI (Enhanced Host Controller Interface) support on The following South Bridge information will display: USB 2.0 connector #2 (-at least one USB 2.0 connector should be enabled for EHCI support.) The options are Disabled and Enabled.
  • Page 64 SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 7: BIOS SATA Configuration Port 0 ~ Port 5 SATA Device Type  Use this item to specify if the SATA port specified by the user should be con- When this submenu is selected, AMI BIOS automatically detects the presence of nected to a Solid State drive or a Hard Disk Drive.
  • Page 65 SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 7: BIOS • Port 0 ~ Port 5 Hot Plug Software Preserve Support Select Enabled to enable hot-plugging support for a port specified by the user, which will allow the user to replace a SATA disk drive installed on this port without sSATA Port 0~ Port 3 shutting down the system.
  • Page 66 SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 7: BIOS • sSATA RAID Option ROM/UEFI Driver ME Firmware Status #2 Select EFI to load the EFI driver for system boot. Select Legacy to load a legacy • Current State driver for system boot. The options are Disabled, EFI, and Legacy. •...
  • Page 67 SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 7: BIOS Maximum Read Request Network Stack Select Auto for the system BIOS to automatically set the maximum size for a read Select Enabled to enable PXE (Preboot Execution Environment) or UEFI (Uni- request for a PCI-E device to enhance system performance. The options are Auto, fied Extensible Firmware Interface) for network stack support.
  • Page 68 SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 7: BIOS VT-UTF8 Combo Key Support *If the item above set to Enabled, the following items will become available for configuration: Select Enabled to enable VT-UTF8 Combination Key support for ANSI/VT100 terminals. The options are Enabled and Disabled. COM1 Console Redirection Settings Recorder Mode Terminal Type...
  • Page 69 SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 7: BIOS SOL/COM2 Console Redirection Settings VT-UTF8 Combo Key Support Select Enabled to enable VT-UTF8 Combination Key support for ANSI/VT100 Use this feature to specify how the host computer will exchange data with the client terminals.
  • Page 70 SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 7: BIOS port to enhance data integrity and network security. Please reboot the system for EMS Console Redirection Settings (Available when EMS a change on this setting to take effect. The options are Enabled and Disabled. Console Redirection is enabled) Use this feature to specify how the host computer will exchange data with the client TPM State...
  • Page 71: Event Logs

    SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 7: BIOS Event Logs Erasing Settings Erase Event Log Use this feature to configure Event Log settings. Select Yes to erase all error events in the SMBIOS (System Management BIOS) log before an event logging is initialized at bootup. The options are No and Yes. When Log is Full Select Erase Immediately to immediately erase all errors in the SMBIOS event log when the event log is full.
  • Page 72: Ipmi

    SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 7: BIOS IPMI When SEL is Full This feature allows the user to determine what the AMI BIOS should do when the Use this feature to configure Intelligent Platform Management Interface (IPMI) system event log is full. Select Erase Immediately to erase all events in the log when settings.
  • Page 73: Security Settings

    SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 7: BIOS Boot Settings Security Settings Use this feature to configure Boot Settings: This menu allows the user to configure the following security settings for the system. Boot Configuration Password Check Setup Prompt Timeout Select Setup for the system to prompt for a password upon entering the BIOS setup Use this item to indicate how many seconds the system shall wait for the BIOS setup utility.
  • Page 74: Save & Exit

    SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Chapter 7: BIOS • Save & Exit Dual Boot Order #7 • Select the Save & Exit tab from the BIOS setup screen to configure the settings Dual Boot Order #8 below. • Dual Boot Order #9 •...
  • Page 75 SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Restore Defaults Select this item and press <Enter> to load the manufacture default settings which are designed for maximum system performance but not for maximum stability. Save As User Defaults Select this item and press <Enter> to save the current BIOS settings as user's default settings for future use.
  • Page 76: Bios Error Beep Codes

    Appendix A: BIOS Error Beep Codes Appendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the system is powered on, errors may occur. Non-fatal errors are those which, in most cases, allow the system to continue the boot-up process.
  • Page 77 SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Notes...
  • Page 78: System Specifications

    LRDIMM (Load Reduced DIMM) or 1 TB of RDIMM (Registered DIMM) DDR4-2400/2133/1866 MHz registered ECC memory Note: refer to Section 5-6 for details on installation. Note: check the Supermicro website (www.supermicro.com) for the latest memory support information. SATA Drive Bays...
  • Page 79 SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL Appendix B: System Specifications Notes Chassis SC217HQ+-R2K04BP2 (2U rackmount) Dimensions: (WxHxD) 17.25 x 3.47 x 28.5 in. (438 x 88 x 724 mm) Weight Gross (Bare Bone): 88 lbs. (40 kg.) System Cooling The system has four 8-cm PWM system cooling fans System Input Requirements AC Input Voltage: 100-240V AC auto-rangeRated Input Current: 16-12A (110- 140V), 12.5-9.5A (180-240V)
  • Page 80 SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL (continued from front) The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear facilities or systems, aircraft, aircraft devices, aircraft/emergency communication devices or other critical systems whose failure to perform be reasonably expected to result in significant injury or loss of life or catastrophic property damage.

Table of Contents