8028 SIP Doorphone
Installation and User Guide
Algo Communication Products Ltd., Burnaby, BC Canada V5J 5L2
www.algosolutions.com
Document #: 90-00054A
- 1 -

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 8028 and is the answer not in the manual?

Questions and answers

Summary of Contents for Algo 8028

  • Page 1 8028 SIP Doorphone Installation and User Guide Algo Communication Products Ltd., Burnaby, BC Canada V5J 5L2 www.algosolutions.com Document #: 90-00054A - 1 -...
  • Page 2: Support

    Important Safety Notice The 8028 SIP Doorphone is designed and tested to comply with EN 60950-1:2006 safety requirements. When the Doorphone Controller is connected to wiring that exits the building, there is potential risk of lightning induced electrical surges or high voltages from fault conditions.
  • Page 3: Table Of Contents

    Table of Contents Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 FCC Compliance .
  • Page 4: Introduction

    Introduction Ideal for secure business entrances, emergency intercom, and residential gates, Algo’s 8028 SIP Doorphone provides hands-free intercom capability, entrance security with door unlock control, rugged weatherproof design, and superior audio performance. Fully compatible with SIP industry standards, the 8028 SIP Doorphone...
  • Page 5: Quick Install & Test

    SIP Server is configured in Step 6 (below). 6. Use the Web Interface to enter the SIP Proxy Server address as well as the user account and password that the 8028 SIP Doorphone will use to register. Also enter the target extension that the Doorphone will call.
  • Page 6: Applications

    Applications Typical Applications for Auxiliary Inputs and Outputs The 8028 architecture and digital link between the Door Station and Controller provides flexible options using the auxiliary inputs and outputs. These are some typical applications: Cancel Ring When Door Opened In a residential or warehouse installation it is not uncommon for the door to be answered in person before the phone is answered.
  • Page 7 Anti-Door Tamper A feature of the 8028 Doorphone is to ring the telephone(s) with a warning alert in the event a door is ajar due to tampering (such as a door blocked open after being legitimately released for a visitor).
  • Page 8: Door Or Gate Control Basics

    Door or Gate Control Basics Control contacts are provided from the Doorphone Controller and are typically used for door strike activation or gate control. For security, the door control relay is located in the Controller to avoid entry by tampering. The Door Station dry contact output (OUT) may be configured for ‘low security’...
  • Page 9 The Door Control relay may also be configured for alternate functionality including In-Use, Ring, and Call Button Press. For more information on applications for the 8028 SIP Doorphone, please visit www.algosolutions.com/8028. The 8028 Doorphone firmware may be modified through the web interface and Algo routinely accepts requests for custom firmware for unique applications.
  • Page 10: Setup And Installation

    Setup and Installation 8028 SIP Doorphone Controller 24V 0.3A 24VDC 0.6A RESET Door Control Relay - Reset Button see Door Control Section Power Input 24V 0.6A Door Station Jack Ethernet Jack. Connect to 6-Wire Modular LAN with access to SIP...
  • Page 11: Programming And Configuration

    To find the IP address of the 8028, press the Call Button on the Door Station. The 8028 will speak its IP address if it has not yet been configured with a SIP Server address. Alternatively, search the network using the 8028 Locator Tool available for download from www.algosolutions.com/8028locator.
  • Page 12 Keep-alive Maintain connection between the 8028 and the SIP Server if the Method 8028 is behind NAT. Period of time where the 8028 will send some information to the Keep-alive Period (seconds) SIP Server to keep the connection alive. The phone number that the 8028 registers with the SIP Server. It Extension will auto-answer any inbound calls.
  • Page 13 Features Audio Settings Speaker audio level in 3 dB steps (Default: 8) Speaker Volume Microphone audio level in 3 dB steps (Default: 7) Microphone Volume DSP Noise Reduction • Full Duplex with Noise Reduction • Full Duplex without Noise Reduction (Default) Allows audible ringback tone to be played on Door Station Ringback Tone speaker until call is answered...
  • Page 14 Door Relay Settings 1-4 digit DTMF code that can be used to unlock the door for Momentary Open Code a brief period of time (as set by the Relay Time field). Leave this field blank to disable this feature. (Default: 6) The duration for which to unlock the door when the Duration Momentary Open Code is entered.
  • Page 15 Auxiliary I/O Settings • In-Use (Default) • Follow Controller Input Controller Output • Ring • Follow Station Input • Call Button Press • Disabled • Door Control • Door Sensor • Door Alarm • In-Use • Door Alarm Door Station Output •...
  • Page 16 • 30 min • None When a Door Alarm condition is detected based on the Max Door Open Alarm Door Open time above being exceeded, then the 8028 can generate a notification call. Call every: • 2 min (Default) • 1 hour •...
  • Page 17 VLAN Priority 802.1p priority. Values are from 0 (best effort) to 7 (highest); 1 represents the lowest priority. Length of time following a request from an 8028 to the DHCP DHCP Timeout (seconds) server that the 8028 will wait before assuming the server is not available.
  • Page 18 If you have forgotten your password, a soft reset will restore the default setting (including all of the device’s default settings). To do this, first disconnect power from the 8028 Doorphone Controller. Then press and hold the Reset button on the back of the device, and while doing this, reconnect the power.
  • Page 19: Nat

    NAT (Network Address Translation) is located between a private network and the Internet. When properly configured, it allows an 8028 installed on a private network to have access to the outside world, such as would be required when using a hosted SIP provider (i.e. a SIP server that is remotely located).
  • Page 20: Auto-Provisioning (Via Tftp)

    Auto-provisioning allows installers to pre-configure 8028 units prior to installation on a network. It is typically used for large deployments. If desired, 8028 configuration files can be automatically downloaded from a TFTP (Trivial File Transfer Protocol) server using DHCP Option 66. Option 66 is a term used by some DHCP vendors to describe DHCP code 66.
  • Page 21: Generating A Specific Configuration File

    8028 will be ready to work immediately after the configuration file is downloaded. The MAC address of each 8028 can be found on the back label of the unit.
  • Page 22: Connections And Lights

    Connections and Lights Auxiliary Dry Contact Outputs Both the Doorphone Controller and Door Station provide a dry contact output for connection to auxiliary devices. Maximum switching capacity is 30 V 50 mA. Default operations are as follows: • Doorphone Controller Output = In-Use (commonly used for camera control) •...
  • Page 23: Led Details

    LED Details Power • On steady: Power is OK, but Ethernet Link not established • Blinks one second on, one second off: Ethernet Link status OK, but IP Address not yet obtained • Light on, blinks off briefly every two seconds: Link and IP Address established successfully Telephone •...
  • Page 24: Connection Details

    Connection Details Door Control Relay Normally Open 24V 0.3A 5 Position Removable Common Terminal Block Normally Closed Auxiliary PWR - 0.3 A (GND) Power PWR + 0.3 A (24 V) Door Station Jack Center Pair (Red & Door Station Green) RJ12 Telephone Jack Middle Pair Dry Contact Input...
  • Page 25: Specifications

    Specifications Compatibility Configuration Web Interface or TFTP Auto-Provisioning Network Address DHCP or static IP address NAT (Network Address STUN Server or Keep-Alive Translation) Speech Full Duplex Capable Codec G.711 Physical Separate Controller and Door Station Controller Power AC Mains Adapter 95-230 V 50/60 Hz Included Indicators Power, Door Station Status, In-Use, Door Unlock Network Connection...
  • Page 26 Door Station Power Provided by Controller link Wiring Up to 1,000 Ft (300 m) 24 AWG single twisted pair to controller Signalling Digital link - bi-directional voice and data Call Button Backlit tactile silicon rubber Connections 6 Position terminal strip - Controller, Aux In, Aux Out Installation Flush or surface mounted using supplied plastic bezel;...
  • Page 27 Note: This page left intentionally blank. - 27 -...
  • Page 28 Algo Communication Products Ltd., Burnaby, BC Canada V5J 5L2 www.algosolutions.com - 28 -...