3.6
Coolant Installation
WARNING
CAUTION
Coolant Fill Cap
Electric Current Is Hazardous.
It is important to have a good earth ground connected to the
workpiece or cutting table.
Commercial Antifreeze Will Cause Torch To
Malfunction.
Use special torch coolant.
Do to high electrical conductivity, DO NOT use tap water or
commercial automotive type antifreeze for torch cooling. A specially
formulated torch coolant is REQUIRED. This coolant also protects
from freezing to -34° C (-29° F).
Operating the unit without coolant will cause permanent damage
to the coolant pump.
Check coolant level frequently.
Remove coolant fi ll cap at front console and fi ll coolant tank with 4
gallons (15 liters) of plasma torch coolant.
Do not fi ll above indicated maximum level.
Reinstall cap.