Carrier MMY-MAP0724FT9UL Service Manual page 237

Multi type super heat recovery multi-i
Table of Contents

Advertisement

No. Part to be replaced
9
Pipe fixing rubber
- detachment/
attachment
072 type
096 type
120 type
Work procedure
This product employs pipe fixing rubber (eyeglass type), combined with a SUS band, to restrain pipes
subject to vibration to improve reliability.
<Use of SUS band - total 5 locations>
Suction pipe ⇔ Distributor
Ø19.05 ⇔ Ø22.22
Rear side
SV41 valve ⇔ Suction pipe
Ø8.0 ⇔ Ø19.05
Front side
This product employs pipe fixing rubber (eyeglass type), combined with a SUS band, to restrain pipes
subject to vibration to improve reliability.
<Use of SUS band - total 10 locations>
SV3C valve <=> Discharge pipe
Ø 6.35 ⇔ Ø 15.88
Rear side
Suction pipe ⇔ SV3F valve
Ø 19.05 ⇔ Ø 9.52
Suction pipe ⇔ Discharge pipe
Ø 28.58 ⇔ Ø 12.7
Suction pipe ⇔ Distributor
Ø 22.22 ⇔ Ø 22.22
SV41 valve ⇔ Suction pipe
Ø 8.0 ⇔ Ø 19.05
SV42 valve ⇔ Suction pipe
Ø 8.0 ⇔ Ø 19.05
Front side
Oil header ⇔ Liquid pipe
Ø25.4 ⇔ Ø12.7
SV42 valve ⇔ Suction pipe
Ø8.0 ⇔ Ø19.05
Oil header ⇔ Liquid pipe
Ø 25.4<=> Ø 12.7
Liquid pipe ⇔ Balance pipe
SV43 valve ⇔ Suction pipe
Ø 15.88 ⇔ Ø 9.52
Ø 8.0 ⇔ Ø 19.05
– 237 –
Remarks
Valve circuit ⇔ Capillary tube
Ø6.35 ⇔ Ø12.7
SV2 valve ⇔ Discharge pipe
Ø6.35 ⇔ Ø15.88
SV2 valve ⇔ Discharge pipe
Ø 6.35 ⇔ Ø 19.05