Carrier MMY-MAP0724FT9UL Service Manual page 145

Multi type super heat recovery multi-i
Table of Contents

Advertisement

Check code
Main
Outdoor 7-segment display
remote
Check
Sub-code
controller
code
01: TK1 oil
circuit error
02: TK2 oil
circuit error
03: TK3 oil
circuit error
04: TK4 oil
circuit error
05: TK5 oil
circuit error
H16
H16
H25
H25
Location
of
Description
detection
I/F
Oil level
detection
circuit error
I/F
TD3 sensor
miswiring
(incomplete
insertion)
Error detection
System status
condition(s)
All stop
No temperature
change is detected
by TK1 despite
compressor 1 having
been started.
No temperature
change is detected
by TK2 despite
compressor 2 having
been started.
No temperature
change is detected
by TK3 despite
compressor 3 having
been started.
No temperature
change is detected
by TK4 despite
compressor having
been started.
No temperature
change is detected
by TK5 despite
compressor having
been started.
Or difference from
other TK sensor
changes within
specified range only
for over the specified
period.
All stop
Discharge
temperature (TD3)
does not increase
despite compressor
3 being in operation.
– 145 –
Check items (locations)
• Check for disconnection of TK1 sensor.
• Check resistance characteristics of TK1
sensor.
• Check for connection error involving TD1,
TD2, TD3, TK1, TK2, TK3, TK4, and TK5
sensors
• Check for faulty operation in SV3E or
SV3F valve.
• Check for clogging in oil equalizing circuit
capillary and faulty operation in check
valve.
• Check for refrigerant entrapment inside
compressor.
• Check for disconnection of TK2 sensor.
• Check resistance characteristics of TK2
sensor.
• Check for connection error involving TD1,
TD2, TD3, TK1, TK2, TK3, TK4, and TK5
sensors
• Check for faulty operation in SV3E or
SV3F valve.
• Check for clogging in oil equalizing circuit
capillary and faulty operation in check
valve.
• Check for refrigerant entrapment inside
compressor.
• Check for disconnection of TK3 sensor.
• Check resistance characteristics of TK3
sensor.
• Check for connection error involving TD1,
TD2, TD3, TK1, TK2, TK3, TK4, and TK5
sensors
• Check for faulty operation in SV3E or
SV3F valve.
• Check for clogging in oil equalizing circuit
capillary and faulty operation in check
valve.
• Check for refrigerant entrapment inside
compressor.
• Check for disconnection of TK4 sensor.
• Check resistance characteristics of TK4
sensor.
• Check for connection error involving TD1,
TD2, TD3,TK1, TK2, TK3, TK4, and TK5
sensors
• Check for faulty operation in SV3E or
SV3F valve.
• Check for clogging in oil equalizing circuit
capillary and faulty operation in check
valve.
• Check for refrigerant entrapment inside
compressor.
• Check for disconnection of TK5 sensor.
• Check resistance characteristics of TK5
sensor.
• Check for connection error involving TD1,
TD2, TD3, TK1, TK2, TK3, TK4, and TK5
sensors
• Check for faulty operation in SV3E valve.
• Check for clogging in oil equalizing
circuit capillary and faulty operation in
check valve.
• Check for refrigerant entrapment inside
compressor.
• Check installation of TD3, TK1, TK2,
TK3 , TK4, TK5 sensor.
• Check connection of TD3, TK1, TK2,
TK3 , TK4, TK5 sensor
connector and wiring.
• Check resistance characteristics of TD3
sensor.
• Check for defect in outdoor P.C. board
(I/F).

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents