Peripheral devices

2.1.2
Peripheral devices
Check the model of the inverter you purchased. Appropriate peripheral devices must be selected according to the capacity.
Refer to the table below to prepare appropriate peripheral devices.
Motor output
Applicable inverter model
(kW)

0.4
FR-A846-00023(0.4K)
0.75
FR-A846-00038(0.75K)
1.5
FR-A846-00052(1.5K)
2.2
FR-A846-00083(2.2K)
3.7
FR-A846-00126(3.7K)
5.5
FR-A846-00170(5.5K)
7.5
FR-A846-00250(7.5K)
11
FR-A846-00310(11K)
15
FR-A846-00380(15K)
18.5
FR-A846-00470(18.5K)
22
FR-A846-00620(22K)
30
FR-A846-00770(30K)
37
FR-A846-00930(37K)
45
FR-A846-01160(45K)
55
FR-A846-01800(55K)
75
FR-A846-02160(75K)
90
FR-A846-02600(90K)
110
FR-A846-03250(110K)
132
FR-A846-03610(132K)

Assumes the use of a Mitsubishi 4-pole standard motor with the power supply voltage of 400 VAC 50 Hz.

Select an MCCB according to the power supply capacity.
Install one MCCB per inverter.
For the use in the United States or Canada, provide the appropriate UL and cUL listed fuse or UL489
molded case
circuit breaker (MCCB) that is suitable for branch circuit protection. (Refer to

Magnetic contactor is selected based on the AC-1 class. The electrical durability of magnetic contactor is 500,000 times. When the magnetic
contactor is used for emergency stops during motor driving, the electrical durability is 25 times.
If using an MC for emergency stop during motor driving, select an MC regarding the drive unit input side current as JEM1038-AC-3 class
rated current. When providing an MC on the inverter output side for switching to commercial power supply during general-purpose motor
operation, select an MC regarding the rated motor current as JEM1038-AC-3 class rated current.
NOTE
• When the inverter capacity is larger than the motor capacity, select an MCCB and a magnetic contactor according to the
inverter model, and select cables and reactors according to the motor output.
• When the breaker on the inverter's input side trips, check for the wiring fault (short circuit), damage to internal parts of the
inverter etc. The cause of the trip must be identified and removed before turning ON the power of the breaker.
14
INSTALLATION AND WIRING
Molded case circuit breaker (MCCB)
or earth leakage circuit breaker (ELB)
(NF, NV type)
5A
5A
10A
10A
15A
20A
30A
40A
50A
60A
75A
100A
125A
150A
175A
225A
225A
225A
400A
page

Input-side magnetic
contactor
S-T10
S-T10
S-T10
S-T10
S-T10
S-T12
S-T21
S-T21
S-T21
S-N25
S-N25
S-N50
S-N50
S-N65
S-N80
S-N95
S-N150
S-N180
S-N220
132.)

MCCB
INV
M
MCCB
INV
M