10.5.2 Attach the Omnii Back Cover
When you are finished with your testing, follow these steps to re-attach the back cover to
your Omnii.
1. Connect all cables from the back cover to the main logic board (trigger/speaker, camera, etc.).
2. Fit the back cover in place on the main housing, making sure no cables are caught in
the seal. If the scanner flex cable for a scanner or imager pod is installed, fold it down so
that it is accessible through the pod opening in the expansion back cover.
3. Install the eight T10 Torx screws in the back cover, and torque to 5 in-lb (0.56 N-m).
Install the screws in the sequence shown here to ensure a consistent seal around
the perimeter.
4. Install the two T6 Torx screws in the front cover above the display, and torque to 2.5 in-lb
(0.28 N-m).
5. If a pod expansion is required on the expansion back cover, attach it now:
i.
Connect the flex cable to the device in the pod expansion module.
ii. Seat the pod in place on the back cover.
iii. Install the four T10 Torx screws to secure the pod to the back cover, and torque to 5 in-lb
(0.56 N-m).

10.5.3 Connect the Test Module to an Expansion Port

Once the back cover has been removed, connect the breakout board flex cable to one of the Omnii
expansion ports. Cables can be designed using the socket and pin descriptions provided in
Section 6.4: "Expansion Ports". Instructions on how to connect your cable to the expansion ports
can also be found in that section.