Allowable Clearances For Undercounter Installation; Allowable Clearances For Closet Installation; Stacked Installation; Removing Packaging Reinforcement - Beko WTE7604XLW0 Owner's Manual

Table of Contents

Advertisement

Installation Instructions

Allowable Clearances for Undercounter Installation

The dimensions are for the recommended spacing. Counter depth should be 23.5-24.5"(60-62 cm).
Custom undercounter installation – Washer only
Minimum counter width should be 50" (127 cm) for a pair of Blomberg washer & dryer.
Custom undercounter installation – Washer & Dryer
50Ó
(127 cm)

Allowable Clearances for Closet Installation

When installed in closet (washer only/washer dryer stacked) :
Sides, Rear, Front 1/2 in. (1.27 cm), Top= 1 in. (2.54 cm)
Closet door ventilation requirement: A louver having minimum 23 in2 (148 cm2) air opening located at
3 in (7.62 cm) from the bottom of closet door.

Stacked Installation

You can stack your Blomberg washer and dryer (model no: DV 16540 NBL00) by using a special
stacking kit (Part No.2967100100). If necessary, consult your dealer or technical service for supplying
the stack kit. In stacked closet installation, following configuration is necessary:
A louver having minimum 23 in2 (148 cm2) air opening located at 3 in (7.62 cm) height from the
bottom of closet door (for washer) & A louver of minimum 46 in2 (297 cm2) air opening located at 3 in
(7.62 cm) distance from the top of closet door (for dryer).

Removing packaging reinforcement

Tilt the washer to remove the packaging reinforcement. Remove the packaging reinforcement by
pulling the ribbon.
Owner's Guide & Installation Instructions