d. Tighten the Screws and Reconnect the connnectors to the PCB.
3.8.2 Replacing The Transformer
a.Disassmble right-cover ()
b. Unfasten all Screw showing in the photo circled with
Screw
the red dotted line and disconnect the connnectors
c. Change the Transformer
d. Tighten the Screws and Reconnect the connnectors .
3.9 Replacing the Sensor
a.Disassmble right-cover and left-cover.
b.Remove the Hexa bolt , C-ring
c. Disassmble Screw showing in the picture (Both sides)
C-ring
Pressure-adjust system
Hexa-bolt
screw
d.Take out Pressure adjust system and Remove Shaft-sensor from machine.