Electrical Requirements - Emerson CF717BS01 Owner's Manual

Table of Contents

Advertisement

BP7483-2 ASHLAND CF717.qxp_BP7483 12/15/15 9:55 AM Page 4
This Manual Is Designed to Make it as Easy as Possible for You to Assemble,
1.3
Place the fan assembly into the upper foam pad with the
top of the motor facing up.
The upper foam pad serves as a holder for the fan during
assembly.
Tools Needed for Assembly
One Phillips head screwdriver
One 1/4" blade screwdriver
Wiring outlet box and box connectors must be of type
required by the local code. The minimum wire would be a
3-conductor (2-wire with ground) of following size:
Your new ceiling fan will require a grounded electrical
supply line of 120 volts AC, 60 Hz, 15 amp circuit.
To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked "Acceptable for
Fan Support of 22.7 kg. (50 lbs.) or less", and use screws
supplied with outlet box. Most outlet boxes commonly
used for support of light fixtures are not acceptable for
fan support and may need to be replaced. Consult a
qualified electrician if in doubt.
Turning off wall switch is not sufficient. To avoid possible
electrical shock, be sure electricity is turned off at the
main fuse box before wiring. All wiring must be in
accordance with National and Local codes and the ceiling
fan must be properly grounded as a precaution against
possible electrical shock.
1. Unpacking Instructions
Install, Operate and Maintain Your Ceiling Fan
One stepladder
One wire stripper
Materials

2. Electrical Requirements

WARNING
!
WARNING
!
(Continued)
Installed Wire Length
Up to 50 ft.
50-100 ft.
WARNING
!
Before assembling your ceiling fan, refer to section on
proper method of wiring your fan (page 12). If you feel
you do not have enough wiring knowledge or experience,
have your fan installed by a licensed electrician.
Controls Sold Separately
SW90 Wall Control (sold separately) may be used with
this 52" Ashland Ceiling Fan. Controls are recommended
for indoor use only.
The outlet box must be securely anchored and capable of
withstanding a load of at least 50 pounds.
If your fan is to replace an existing ceiling light fixture, turn
electricity off at the main fuse box at this time and remove
the existing light fixture.
WARNING
!
To avoid fire or shock, follow all wiring instructions
carefully.
Any electrical work not described in these
instructions should be done or approved by a licensed
electrician.
Please
call
Emerson
1-800-654-3545 if you have any questions about
installation and operation of this ceiling fan.
4
Wire Size A.W.G.
14
12
technical
support
at
ETL Model No.: CF717-1