Lamp Maintenance; Approved Lamp; Lamp Life And Monitoring Lamp Hours - Martin Exterior 1200 Wash User Manual

Table of Contents

Advertisement

8.5 Lamp maintenance

8 . 5 . 1 A p p r o v e d l a m p
Important! The Exterior 1200 Wash is designed to use only the lamp specified below.
Installing any other model may cause damage to the luminaire that is not
covered by the product warranty.
Lamp
Philips MSD 1200
Data subject to change. Refer to lamp manufacturer's specifications for latest information.
8 . 5 . 2 L a m p l i f e a n d m o n i t o r i n g l a m p h o u r s
A discharge lamp's quartz bulb weakens over time, significantly increasing the risk of lamp
explosion. Always replace a discharge lamp before it reaches the limit of its average life
(see table above). In large installations, replacing all lamps at the same time will simplify
replacement schedules.
The Exterior 1200 Wash has built-in resettable counters that you can use to monitor the
number of hours the lamp has been used and the number of times the lamp has been
struck (started). The counters can be checked in the onboard control panel or using the
MUM application. Check the counter as necessary, and reset the luminaire's Resettable
Lamp Hours and Resettable Lamp Strikes counters each time you install a new lamp
A. Checking and resetting the lamp life counters using the onboard control
panel
The onboard control panel displays the lamp hours and lamp strike counters in the L a m p
S t a tu s display every few seconds until you enter the control menus.
To reset the counters using the onboard control panel:
1. Open the P er s o n al i t y menu, navigate to the counters and press Enter to display.
2. To return the resettable lamp hours and lamp strikes counters to zero, select R es e t
a ll c o un t e rs , press Enter and confirm.
B. Checking and resetting the lamp life counters using MUM
To reset the counters:
1. Connect a PC and DABS1 adaptor to the Exterior 1200 Wash via the service port in
the connections compartment.
2. Power on the Exterior 1200 Wash and start the MUM application. The application will
automatically detect an Exterior 1200 Wash if it is powered on and correctly
connected. It will also retrieve the current settings on the luminaire and display them.
Average life
Color temp.
3000 hours
6000 K
Table 4: Lamp specifications
Lamp maintenance
CRI (Ra8)
Output
80
92 000 lm
61