5. With the shift lever in the Neutral position, engage the
PTO, and set the hand throttle.
6. Ensure that the agitation control valve is in the On
position.
7. Set the master boom switch and boom switches to the
On positions to begin spraying.
8. Allow all of the water in the tank to spray out though
the nozzles.
9. Check the nozzles to ensure that they are all spraying
correctly.
10. Set the master boom switch to the Off position,
disengage the PTO, and stop the engine.
11. Repeat steps 3 through 10 at least 2 more times to
ensure that the spray system is fully cleaned.
12. Clean the strainer; refer to Cleaning the Suction
Strainer, page 35.
Important
If you used wetable powder chemicals,
clean the strainer after each tank.
13. Using a garden hose, spray off the outside of the
sprayer with clean water.
14. Remove the nozzles and clean them by hand. Replace
damaged or worn nozzles.

Stowing the Boom Extensions

Use the boom restraints to lock the boom extensions in the
X position when you are not spraying.
1. Pivot the left boom extension into the upright position.
Important
Do not force the boom extension past the
restraint hook when stowing or you may damage the
extension and nozzles.
2. Push up on the left restraint knob to compress the
spring and extend the hook.
3. With the spring compressed, rotate the hook to catch
the boom extension frame.
4. Release the knob allowing the hook to catch the boom
extension frame and secure it to the boom holder.
5. Repeat steps 1-4 with the right boom extension and
right boom holder.