Important
The paddle wheel assembly will only fit
into the body one way. Align the pin of the paddle wheel
assembly with the hole in the flowmeter body. Do not
force the paddle wheel assembly into the body in any
other orientation.
5. Install the retaining cap.
3
1
2
Figure 38
1. Retaining cap
2. Paddle wheel assembly
Cleaning the Suction Strainer
Clean the suction strainer daily. If you are using wetable
powders, clean it after every tank.
1. Remove the retainer from the red fitting attached to
the large hose on the top of the tank.
Figure 39
1. Suction strainer
2. Disconnect the hose from the tank.
3. Pull the strainer out of the hole.
3. Flowmeter body
1
35
4. Clean the strainer with clean running water.
5. Replace the strainer, seating it fully into the hole.
6. Connect the hose to the top of the tank and secure it
with the retainer.