Storing the Battery
If the machine will be stored for more than 30 days, remove
the battery and charge it fully. Either store it on the shelf or
on the machine. Leave the cables disconnected if it is stored
on the machine. Store the battery in a cool atmosphere to
avoid quick deterioration of the charge in the battery. To
prevent the battery from freezing, make sure it is fully
charged.

Cleaning the Suction Strainer

Clean the suction strainer daily. If you are using wetable
powders, clean it after every tank.
1. Remove the retainer from the red fitting attached to the
large hose on the top of the tank.
Figure 59
1. Suction strainer
2. Disconnect the hose from the tank.
3. Pull the strainer out of the hole.
4. Clean the strainer with clean running water.
5. Replace the strainer, seating it fully into the hole.
6. Connect the hose to the top of the tank and secure it
with the retainer.
Note: Other screen meshes are available. Contact your
Authorized Toro Dealer.

Cleaning the Flowmeter

Occasionally, the flowmeter may need to be cleaned to
remove an obstruction, as follows:
1. Remove the retaining cap from the flowmeter body
(Fig. 60).
1
2
1. Retaining cap
2. Paddle wheel assembly
1
2. Carefully pull the paddle wheel assembly from the
body.
3. Use warm water, a soft-bristled brush, and a mild
detergent as necessary to clean the flowmeter body and
paddle wheel. Remove any small metallic debris.
Important
flowmeter.
4. Install the paddle wheel assembly into the flowmeter
body.
Important
the body one wa., Align the pin of the paddle wheel
assembly with the hole in the flowmeter body. Do not
force the paddle wheel assembly into the body in any other
orientation.
5. Install the retaining cap.

Stowing the Boom Extensions

Use the boom restraints to lock the boom extensions in the
X position when you are not spraying.
1. Pivot the left boom extension into the upright position.
Important
restraint hook when stowing or you may damage the
extension and nozzles.
2. Push up on the right restraint knob to compress the
spring and extend the hook.
3. With the spring compressed, rotate the hook to catch the
boom extension frame.
44
Figure 60
3. Flowmeter body
Do not use solvents or fuel to clean the
The paddle wheel assembly will only fit into
Do not force the boom extension past the
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Multi-pro 1200

Table of Contents