Actuator Boom Electrical Connection; Installing Nozzles; Before Operating; Filling The Fresh Water Tank - Toro 41229 Operator's Manual

Spray system heavy duty workman vehicles
Hide thumbs Also See for 41229:
Table of Contents

Advertisement

4. With the boom actuator at full extension, the
break-away pivot gusset should just touch the center
boom frame slot (Fig. 28).
1
Figure 28
1. Break-away pivot gusset
2. Center boom frame slot
5. If necessary, loosen the end nut that secures the
adjustable clevis and adjust the jam nut to allow
correct boom actuator extension. (Fig. 27).
6. Tighten the end nut to secure the clevis adjustment.
Important
The booms should not be parallel to the
ground when fully down (Fig. 27). You control each
boom's orientation to the ground using the switches.
Adjusting the booms in any other manner may damage the
boom or the actuators.
The extension boom nozzles must be spaced 20 inches
apart. Verify this spacing and adjust the nozzles if
necessary.
Actuator Boom Electrical
Connection
1. Connect the connector at the rear of the machine with
the blue and orange wires to the connector on the left
actuator.
2. Connect the connector at the rear of the machine with
the yellow and green wires to the connector on the
right actuator.
3. Seal the connections you made to the actuator wire
connectors with silicone sealant.
4. Secure any loose wires using cable ties.
3
2
m–7433
3. Boom actuator
23

Installing Nozzles

The nozzles you use to apply your chemicals vary
depending on the rate of application that you need;
therefore, nozzles are not supplied with the kit. To obtain
the correct nozzles for your needs, contact your
Authorized Toro Distributor and be prepared to give them
then following information:
• The recommended application rate in US gallons per
acre, US gallons per 1000 sq ft, or liters per hectare.
• The target speed or the vehicle in miles per hour or
kilometers per hour.
• The nozzle spacing (typically 20 inches or 50 cm).
To install a nozzle, complete the following:
1. Thread the nozzle into the nozzle receptacle.
2. Slide the nozzle receptacle over the nozzle fitting on a
turret.
3. Turn the nozzle clockwise to lock the cams on the
receptacle in place.
4. Verify the fan portion of the nozzle faces down.
See the Installation Instructions accompanying the
nozzles for more information.

Before Operating

Filling the Fresh Water Tank

The sprayer is equipped with a fresh water tank (Fig. 29)
for you to wash chemicals off of your skin, eyes, or other
surfaces in the case of accidental exposure. Always fill the
fresh water tank with clean water before handling or
mixing any chemicals.
1
2
3
Figure 29
1. Filler cap
2. Fresh water tank
To open the fresh water tank spigot, turn the lever on the
spigot toward the front of the sprayer.
m–7434
3. Spigot