(2) Change of the setting
1. Automatic presser lifting
FL ON
: Auto-lifter device becomes effective.
FL OFF : Auto-liffter function does not work.
(Standard at the time of delivery)
(Similarly, the presser foot is not automatically lifted when programmed stitching is completed.)
1. To perform re-turning ON of the power, be sure to perform after the time of one second or more
has passed.
(If ON/OFF operation of the power is performed quickly, setting may be not changed over well.)
2. Auto-lifter is not actuated unless this function is properly selected.
3. When "FL ON" is selected without installing the auto-lifter device, starting is momentarily de-
layed at the start of sewing. Be sure to select "FL OFF" when the auto-lifter is not installed.
2. Ineffective setting of the automatic reverse feed stitching
Standard Adjustment
– 96 –