Adjustment Procedure
1. Remove rubber cap
needle bar bracket and adjust the height of the needle bar.
2. After adjusting the height, equally adjust the clearance A between
needle
and needle hole
bar with setscrew
in the face plate, loosen setscrew
in the throat plate and fix the needle
in the needle bar bracket.
A
Equal
Results of Improper Adjustment
in the
– 25 –
o When the height of the needle
is excessively different, stitch
skipping, needle breakage,
thread breakage, etc. will be
caused.