weather influences like rain and dust from above; so the HEATSCOPE® has to be installed under a roof,
an overhang or in combionation with the optional available weather shield.
4. As soon as the unit is connected to a power source and switched on using an „ON/OFF" switch or
other operating component, it takes a maximum of 15-30 seconds until it reaches its operating tempe-
rature.
5. CAUTION: Risk of burns! The front screen (approx. 572 °F) and protective fin front (approx. 572 °F)
gets very hot when the unit is operating.
Do not cover either part of the front or the entire front of the radiant heater. Do not touch any part of
the HEATSCOPE® during operation and up to 30 minutes after switching it off.
6. For your own safety, never dry textiles or other materials using the HEATSCOPE®. Covering the
radiant heater may result in a fire! Always maintain a distance from the heating surface of the HEAT-
SCOPE® of at least 150 cm from textiles, cloth and other easy inflammable soft materials.
7. Ensure that cables, furniture, flammable materials or other objects do not come into contact with
the surface of the radiant heater and never cover the unit. Under no circumstances should the unit be
covered or enclosed with insulating or similar materials. Adequate ventilation surrounding the heater
must be ensured at any time. Ledgers, beams and rafters must not be cut into or grooved to install the
infrared heater.
When installing the HEATSCOPE® radiant heater, ensure that the lower edge of the unit is at least
70.87 inch from the ground and the safety clearances from the wall and ceiling set out in this manual
are maintained. Always maintain a distance from the heating surface of the HEATSCOPE® of at least
59.06 inch from textiles, cloth and other easy inflammable soft materials.
8. Disconnect the radiant heater from the power supply before cleaning it, adjusting the angle or
removing it from the wall/ceiling. Wait until the heating elements are not glowing any more and the
housing is noticably cooled down. If buried cables are used, switch off the power using an omnipolar
switch.
9. The HEATSCOPE® features an omnipolar „ON/OFF" switch. The unit can be controlled manually
either using an IR remote control (supplied, depending on the model) or a selector switch on the unit
itself (depending on the model as well). The unit must be connected to a residual current circuit brea-
ker and a fuse on the installation side.
10. The unit must only be used with an approved isolating system, which must be built in the existing
electrical installation acc. to the facility regulations. The heater comes as standard with a separate
open-ended cable for connection purposes.
11. The power cable or buried cable with omnipolar switch may only be replaced by a professional
specialist electrical company enlisted or approved by the manufacturer. Heating elements, other
components or parts of the housing may only be replaced by a service organisation enlisted by the
manufacturer.
If you yourself or someone enlisted by you carries out repairs, they will not be covered by the guaran-
tee. Improper repairs and incorrect installation or operation shall invalidate the guarantee immediate-
ly.