7.1. CONTROL EQUIPMENT
7.1. ZUBEHÖR
PT-1000 IP65
Wall-mounted temperature
sensor
Protection degree: IP65
Operation temperature
range:
-20 ... +100
R10
Signal distributor
Protection degree: IP54
Operation temperature
range: 0 ... +40
Number of devices possible
to connect: up to 10 (up to 5
for LEO FB 95)
SRS | SRV2d
Two-way valve with
actuator
Protection degree: IP44
Supply voltage: 200 – 240V
50/60Hz
Max. medium temperature:
o
+130
C
Max. operating pressure:
1,6MPa
Kvs: SRS–3.5; SRV2d–5
Connection: SRS – ½";
SRV2d – ¾"
Runtime: 2,5min.
Mounting: on the return line
of the heat medium from the
heater.
SRS3d | SRV3d
Three-way valve with
actuator
Protection degree: IP40
Supply voltage: 200 – 240V
50/60Hz
Max. medium temperature:
o
+95
C
Max. operating pressure:
2MPa
Kvs: SRS3d–3,4; SRV3d–7
Connection: SRS3d – ½";
SRV3d – ¾"
Runtime: 7s
Mounting: on the supply line
of the heating medium to
the heater.
Czujnik naścienny pomiaru
temperatury
Stopień ochrony: IP65
Zakres temperatury pracy:
-20 ... +100
o
C
Rozdzielacz sygnału
Stopień ochrony: IP54
Zakres temperatury
o
pracy: 0...+40
C
Ilość obsługiwanych
urządzeń: do 10 (do 5 dla
LEO FB 95)
Zawór dwudrogowy
z siłownikiem
Stopień ochrony: IP44
Napięcie zasilania: 200 –
240V 50/60Hz
Maks. temperatura
czynnika: +130
Maks. ciśnienie robocze:
1,6MPa
Kvs: SRS–3.5; SRV2d–5
Przyłącze: SRS – ½";
SRV2d – ¾"
Czas otwarcia: 2,5min.
Montaż: na powrocie
czynnika grzewczego z
nagrzewnicy
Zawór trójdrogowy
z siłownikiem
Stopień ochrony: IP40
Napięcie zasilania: 200 –
240V 50/60Hz
Maks. temperatura
czynnika: +95
Maks. ciśnienie robocze:
2MPa
Kvs: SRS3d–3,4; SRV3d–7
Przyłącze: SRS3d – ½";
SRV3d – ¾"
Czas przebiegu: 7s
Montaż: na zasilaniu
nagrzewnicy czynnikiem
grzewczym
7.1. ELEMENTY AUTOMATYKI
7.1. СОСТАВНЫЕ ЭЛЕМЕНТЫ СИСТЕМЫ УПРАВЛЕНИЯ
Wandsensor für
Temperaturmessung
Schutzklasse: IP65
Bereich der
o
C
Betriebstemperatur:
-20 ... +100
Signalverteiler
Schutzklasse: IP54
Betriebstemperatur:
o
o
0 ... +40
C
Anschluss mehrerer Geräte
möglich:
max. 10 LEO FB
9/15/25/45/65 und max. 5
LEO FB 95
2-Wege-Regelventil mit
Stellmotor
Schutzklasse: IP44
Versorgungsspannung:
200 – 240V 50/60Hz
Max. Temperatur des
o
C
Mediums: +130
Max. Betriebsdruck:
1,6MPa
Kvs: SRS–3.5; SRV2d–5
Anschluss: SRS – ½";
SRV2d – ¾"
Laufzeit: 2,5min.
Montaż: na powrocie
czynnika grzewczego z
nagrzewnicy
3-Wege-Regelventil mit
Stellmotor
Schutzklasse: IP40
Versorgungsspannung:
200 – 240V 50/60Hz
Max. Temperatur des
o
C
Mediums: +95
Max. Betriebsdruck: 2MPa
Kvs: SRS3d–3,4; SRV3d–7
Anschluss: SRS3d – ½";
SRV3d – ¾"
Laufzeit: 7s
Montage: am Rücklauf des
Mediums
Внешний датчик
температуры
Степень защиты: IP65
Диапазон рабочей
температуры:
o
-20 ... +100
C
Распределитель сигнала
Степень защиты: IP54
Диапазон рабочей
температуры:
C
0 ... +40
Количество
обслуживанных
аппаратов: до 10 шт (до 5
для LEO FB 95)
Двухходовой клапан
с сервоприводом
Степень защиты: IP44
Напряжение питания:
200 – 240В 50/60Гц
Макс. температура
o
теплоносителя: +130
C
Макс. рабочее давление:
1,6MПa
Kvs (коэффициент
пропускания): Kvs: SRS–
3.5; SRV2d–5
Присоединительные
патрубки: SRS – ½";
SRV2d – ¾"
Время открытия: 2,5 мин
Установка: на возврате
(выходе) воды из
теплообменника.
Трехходовой клапан с
сервоприводом
Степень защиты: IP40
Напряжение питания:
200 – 240В 50/60Гц
Макс. температура
o
теплоносителя: +95
C
Макс. рабочее давление:
2MПa
Kvs (коэффициент
пропускания): SRS3d–3,4;
SRV3d–7
Присоединительные
патрубки: SRS3d – ½";
SRV3d – ¾"
Время открытия: 7 сек
Установка: на подаче
(входе) теплоносителя в
теплообменник.
o
C
o
C
o
C
o
C