Steam jacketed kettle
with standard electronic ignition (36 pages)
Summary of Contents for Groen OM-TDB/7
Page 1
IMPORTANT INFORMATION2 2KEEP FOR OPERATOR KEEP FOR OPERATOR KEEP FOR OPERATOR KEEP FOR OPERATOR2 2IMPORTANT INFORMATION IMPORTANT INFORMATION IMPORTANT INFORMATION IMPORTANT INFORMATION OM-TDB/7 OPERATOR MANUAL Part Number 121002 DOMESTIC MODEL: TDB/7 Steam Jacketed Kettle Self-Contained Electrically heated Table top mounted Tilting THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE.
OM-TDB/7 IMPORTANT — READ FIRST — IMPORTANT CAUTION: BE SURE ALL OPERATORS READ, UNDERSTAND AND FOLLOW THE OPERATING INSTRUCTIONS, CAUTIONS, AND SAFETY INSTRUCTIONS CONTAINED IN THIS MANUAL. WARNING: THIS UNIT IS INTENDED FOR USE IN THE COMMERCIAL HEATING, COOKING AND HOLDING OF WATER AND FOOD PRODUCTS, PER THE INSTRUCTIONS CONTAINED IN THIS MANUAL.
Page 3
FOLLOW THE DIRECTIONS ON THE LABEL OF THE CLEANER TO BE USED. CAUTION: USE OF ANY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY GROEN OR THEIR AUTHORIZED DISTRIBUTORS CAN CAUSE OPERATOR INJURY AND DAMAGE TO THE EQUIPMENT, AND WILL VOID ALL WARRANTIES.
OM-TDB/7 Equipment Description The Groen TDB/7 is a table top, tilting, steam A built-in steam generator, sized for the kettle jacketed kettle with a thermostatically controlled, capacity and heated by electricity, delivers steam self-contained, electrically-heated steam supply and into the jacket. “Airless” operation of the steam appropriate controls, mounted on a sturdy base.
Page 6
OM-TDB/7 New/Current Models Pre- Feb. 1995 Models Optional equipment available with any model: 1. Stand that supports the unit and holds a pan in position for filling 2. Lift-off cover 3. Basket insert 4. Fill faucet 5. Manual stirrers 6. Motor driven agitator...
OM-TDB/7 Inspection & Unpacking The unit will arrive in a heavy shipping carton and will Write down the model number, serial number, and be attached to a skid. Immediately upon receipt, installation date, and retain this information for future inspect the carton carefully for exterior damage.
4. Bringing the electrical service through the panel. Any mechanical or electrical changes must be entrance at the rear of the support housing, approved in by Groen’s Food Service Engineering making a watertight connection with the Department. incoming lines. (A BX connection is not recommended.)
5. To shut down the unit, turn the thermostat for use. If the unit does not function as intended, dial to “OFF”. contact your local Groen Certified Service Agency. A simple turn of the thermostat controls the Groen TBD/7 Kettle...
OM-TDB/7 Operation (old models). If the level is too low, see “Jacket Filling and Water Treatment” on page 10 of this manual. 2. Check the pressure gauge. If the gauge does not show 20 to 30 inches of vacuum (that is, a reading of 20 to 30 below 0), see “Jacket Vacuum”...
Page 11
OM-TDB/7 WARNING WHEN TILTING KETTLE PRODUCT TRANSFER: WEAR PROTECTIVE OVEN MITT AND PROTECTIVE APRON. 2) USE DEEP CONTAINER TO CONTAIN AND MINIMIZE PRODUCT SPLASHING. WARNING 3) PLACE CONTAINER ON STABLE, FLAT AVOID ALL DIRECT CONTACT WITH HOT SURFACE, AS CLOSE TO KETTLE AS SURFACES.
OM-TDB/7 2. Basket Insert AVOID ALL DIRECT CONTACT WITH HOT An optional kettle basket insert can assist in FOOD WAT ER IN THE KETTLE. cooking water-boiled products including DIRECT CONTACT COULD RESULT eggs, potatoes, vegetables, shell fish, pasta SEVERE BURNS.
OM-TDB/7 Maintenance NOTICE: Contact Groen or an authorized Groen representative when repairs are required. 1. Periodic Maintenance month. Test the valve with the kettle A Maintenance & Service Log is provided at operating at 15 psi (105 kPa), by holding the test lever for at least 5 seconds.
Page 14
OM-TDB/7 lever or ring for about 1 second. Repeat b. Tilt kettle 90° to a full pour position. Remove fill plug with open-end wrench or this step, then let the pull ring or valve crescent wrench. lever snap back into the closed position.
Page 16
OM-TDB/7 4. Water Treatment Procedure Model Kettle Jacket Capacity Capacity TDB/7-20 20 quarts 4 quarts WARNING TDB/7-40 40 quarts 5 quarts TO AVOID INJURY, READ AND FOLLOW PRECAUT IONS STATED ON THE 5. Component Replacement LABEL WAT ER T REATMENT COMPOUND.
OM-TDB/7 Cleaning 1. Suggested Tools: Prepare a hot solution of the detergent/ Cleaner, such as Klenzade HC-10 or HC- cleaning compound as instructed by the 32 from ECOLAB, Inc. supplier. Clean the unit thoroughly. A cloth moistened with cleaning solution b.
Page 18
The outside of the unit may be polished Groen Delimer/Descaler (Part Number with a stainless steel cleaner such as 114800) or Lime-Away from Ecolab, in “Zepper” from Zep Manufacturing Co.
OM-TDB/7 Troubleshooting Your Groen kettle is designed to operate smoothly and efficiently if properly maintained. However, the following is a list of checks to make in the event of a problem. Wiring diagrams are furnished inside the service panel. If an item on the list is followed by X, the work should be done by a qualified service representative.
OM-TDB/7 l. Parts List (For units manufactured before September 1, 1988) * To order parts, contact your Groen Certified Service Agency. Supply the model designation, part description, part number, quantity, and, where applicable, voltage and phase. Description Part No. Description Part No.
Page 21
OM-TDB/7 (For units manufactured before September 1, 1998)
OM-TDB/7 Parts List (For units manufactured between September 1, 1988 and July 1, 1992)* To order parts, contact your Groen Certified Service Agency. Supply the model designation, part description, part number, quantity, and, where applicable, voltage and phase. Description Part No.
Page 23
OM-TDB/7 (For units manufactured between September 1, 1988 and July 1, 1992)
OM-TDB/7 Parts List (For units manufactured between July 1, 1992 and Feb. 6, 1995) * To order parts, contact your Groen Certified Service Agency. Supply the model designation, part description, part number, quantity, and, where applicable, voltage and phase. Description Part No.
Page 25
OM-TDB/7 (For units manufactured between July 1, 1992 and February 6, 1995)*...
OM-TDB/7 Replacement Kettle Body Parts List (For units manufactured after Feb. 6, 1995) * * Date of manufacture stamped on National Board data plate.
Page 27
OM-TDB/7 Replacement Mechanical Parts List (For units manufactured after Feb. 6, 1995) * * Date of manufacture stamped on National Board data plate.
Page 28
OM-TDB/7 Replacement Electrical Parts List (For units manufactured after Feb. 6, 1995) * Date of manufacture stamped on National Board data plate.
Page 29
OM-TDB/7 Parts List (For units manufactured after Feb. 6, 1995) * To order parts, contact your Groen Certified Service Agency. Supply the model designation, part description, part number, quantity, and, where applicable, voltage and phase. Description Part No. Description Part No.
OM-TDB/7 Service Log Model No. _______________________________ Purchased From _________________________ Serial No. _______________________________ Location ________________________________ Date Purchased __________________________ Date Installed ___________________________ Purchase Order No. ______________________ For Service Call __________________________ Date Service Performed Performed By References KLENZADE SALES CENTER ECOLAB. Inc. NATIONAL SANITATION FOUNDATION 370 Wabasha 3475 Plymouth Rd.
Groen Equipment. This warranty does not cover defects caused by improper installation, abuse, careless operation, or improper maintenance of equipment.
Page 44
OM-TDB/7 (Revised 12/97) 1055 Mendell David Drive Jackson, MS 39212 Part Number 121002 Telephone 601 372-3903 Fax 601 373-9587...
Need help?
Do you have a question about the OM-TDB/7 and is the answer not in the manual?