Emptying Of The Burned Gases From Environment; Gas Connection - Proline PGH461SS-B Operating And Installation Instructions

Table of Contents

Advertisement

Available languages

Available languages

3. Part : INSTALLATION AND PREPARATIONS FOR USE

3.2. Emptying of the Burned Gases from Environment

The cooking appliances that operate with gas, throw the burned gas wastes out
directly to the outside or through cooker hoods that are connected to the a
chimney that opens directly to the outisde. If it is not possible to install a
cooker hood, it is required to set an electric fan into the window or wall that has
access to fresh air. This electric fan must have the capacity to change the air of
the kitchen environment 4-5 times of its own volume of air per hour.
There are some factors that must be paid attention to while installing your
oven. Surely be very careful to while installing your oven. Pay attention to our
instructions in order to be able to prevent any problems and/or dangerous
situations that may occur later.
Pay attention not to install it near the refrigerator, there must be no flammable
materials such as curtains or any kind of fabric, that will burn quickly. The
furniture close to oven must be manufactured resistant to temperatures up to
0
80 C. The minimum heights from the oven's pan and wall cupboards and cooker
hoods with fan over the oven, are shown as above. Thus, the cooker hood must
be at minimum 650mm height from the cooker pan. If there is no cooker hood,
this height must not be less than 750mm.

3.3. Gas connection

The connection of the appliance should be performed in accordance with local
and international standards and regulations applicable. You can find the
information related to appropriate gas types and appropriate gas injectors on
technical data table. If the pressure of used gas is different than these values
stated or they are not stable in your area, it is required to install a pressure
regulator on the gas inlet. It is certainly required to contact a qualified service
agent to make these adjusments.
If the gas connection is made by a flexible hose that is fixed on the gas inlet of
appliance, it must be fixed by a pipe collar as well. Connect your appliance with
a short and durable hose that is as close as possible to the gas source. The
hose's permitted maximum lenght is 1.5m. The hose that brings gas to the
appliance must be changed once a year for your security.
The points that must be checked during flexible hose assembly
The hose must be kept clear from areas that may heat up to temperatures in
0
excess of 50 C. The hose must not be ruptured, bent or folded. The hose must
be kept clear of sharp corners, moving objects and should not be damaged in
any way. Before assembly, you must check whether there is any damage. As
gas is turned on, all connection parts and hose must be checked for gas leaks
using a soap solution.
8

Advertisement

Table of Contents
loading

Table of Contents