Setting The Lamp Relay Interval, Lamp Select Is Set To Single - Barco PH series User And Installation Manual

Hide thumbs Also See for PH series:
Table of Contents

Advertisement

8.2

Setting the lamp relay interval, LAMP SELECT is set to SINGLE

How to set
1. Display the INSTALLATION 1 menu.
2. Select LAMP SELECT by pressing the ▲ or ▼ key.
LAMP SELECT
Image 8-8
3. Press the ENTER key.
4. Select SINGLE
LAMP SELECT
LAMP SELECT
Image 8-9
5. Press the ENTER key.
6. Select LAMP RELAY by pressing the ▲ or ▼ key.
LAMP RELAY
Image 8-10
7. Select 24H
24H
At the time of power-on or menu setting
LAMP 1
LAMP 2
Image 8-11
1 WEEK
At the time of power-on or menu setting
LAMP 1
LAMP 2
Image 8-12
8. Press the ENTER key.
When you select 24H
24H
NEXT LAMP RELAY
2 4 H
0
1
2
3
OK
Image 8-13
1 WEEK
9. Move the key cursor using the direction keys to select the number you want to enter and then press the ENTER key.
R5905597 PHXX SERIES 20/05/2014
Downloaded From projector-manual.com Barco Manuals
The lamps are automatically switched and used alternately.
DUAL
by pressing the ◄ or ► key.
SINGLE
24H
or 1 WEEK
by pressing the ◄ or ► key.
The lamps are switched to each other every day.
2
3
4
5
1
Illuminating
Off
The lamps are switched to each other every week.
2
3
4
5
1
Off
Illuminating
or 1 WEEK
, the box to set the lamp relay interval is displayed.
DEL
4
5
6
7
8
9
CLEAR
CANCEL
6
7
8 (days)
6
7
8 (days)
8. Lamp relay
83

Advertisement

Table of Contents
loading

Table of Contents