When you install a hot-swap storage drive, save the removed dummy storage-drive tray from the drive bay in
the event that you later remove the hot-swap storage drive and need the dummy tray to cover the place.
Attention: An unoccupied drive bay without any other protection might impact the EMI integrity and cooling
of the server, which might result in overheating or component damage. To maintain the EMI integrity and
cooling of the server, install a new hot-swap storage drive as soon as you remove the failing one or
the dummy tray.
Before you begin, print all the related instructions or ensure that you can view the PDF version on another
computer for reference.
Notes:
• Depending on the model, your server might look different from the illustrations in this topic.
• Use any documentation that comes with the hot-swap storage drive and follow those instructions in
addition to the instructions in this topic.
To install or replace a hot-swap storage drive, do the following:
1. Read the following storage drive installation rules:
• Follow the order of the storage drive bays when installing a storage drive. See "Front view of the
server" on page 17 to locate the storage drive bays in your server.
• For RAID configuration, the storage drives must be the same type with the same capacity if they are
within a single RAID array. For more information, see "Configuring RAID" on page 65.
2. Open the front door (if available).
3. Locate the appropriate storage-drive bay. See "Front view of the server" on page 17.
128