FC-21 Flow Computer

6.2 EZ Setup

The EZ Setup routine is a quick and easy way to configure the unit for the most
commonly used instrument functions.
measuring Volumetric Flow using a high level, DC Pulsing flow sensor. Entering
the EZ Setup mode automatically sets many features. This may cause any
previously programmed information to be lost or reset.
customized configuration, see sections 6.3 and 6.4.
Menus
6.2.1
SELECT OPERATE STATE
TOP LEVEL
Run
SETUP MENU
SELECT EZ SETUP
6.2.2
EZ Setup
Submenu
Groups
ARE YOU SURE?
No
INSTRUMENT TYPE
Rate/Tot
RATE TIME BASE
Sec
RATE DEC PLACES
TOTAL VOLUME UNITS
TOTAL DEC PLACES
K_FACTOR TYPE
Avg
AVERAGE KA-FACTOR
LINEAR TABLE KA
Fre01:######## Hz
LINEAR TABLE KA
KA--01:##########
FS ANALOG OUT 20mA
RATE
TOTAL
Display
Setup
Test
ENTER
ENTER
Yes
ENTER
Batch
ENTER
Min
Hour
Day
ENTER
ENTER
gal
ENTER
ENTER
LinTbl
UVC
ENTER
####### P/gal
ENTER
ENTER
#######gal/m
ENTER
00.0 gal/m
0 gal
This setup assumes that you are
Select Setup to enter the instrument
setup routine.
Press ENTER to begin EZ Setup
routine.
Confirm that you want to run EZ Setup.
Caution: Any previous program
settings may be lost or reset.
Instrument Type.
Select the appropriate rate time base.
Enter the desired rate decimal location.
0-3 decimal places allowed.
0
Enter the desired totalizer units label.
Enter the desired totalizer decimal
location. 0-3 decimal places allowed.
0
Enter the desired K-Factor Type.
If Average selected, Enter the desired
Average K-Factor.
If LinTbl or UVC selected,
Enter the desired frequency/ K-Factor
pair for each point in the Linearization
Table.
Enter a frequency of 0 for any point
other than Fre01 to exit Linearization
Table setup.
Enter the desired full scale setting for
the analog output.
Return to Run Mode
20
For a complete
Notes