F . A i r S h u t t e r S e t t i n g
Air shutter settings may be adjusted by a qualified
installer at the time of installation. The air shutter is set at
the factory for minimum vertical vent run. Adjust air
shutter for longer vertical runs. See Figure 9.6.
Refer to Gas Service Access instructions in Section
9.C to access the air shutter.
Loosen the 1/4 in. (6 mm) screw.
DETAIL
Figure 9.6 Air Shutter Location
Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15
42
Twist shutter to adjust.
Shutter may be open for longer horizontal vent runs.
Do not close the air shutter more than 1/16 in. (2
mm) for NG or 1/4 in. (6 mm) for ULPG
Tighten the screw.
NOTICE: If sooting occurs, provide more air by opening
the air shutter.
Air Shutter Settings
MEZZO-1000-AU
MEZZO-1300-AU
MEZZO-1300ST-AU
GLASS REFRACTORY
KIT
LOG KIT
MEZZO-1600-AU
GLASS REFRACTORY
KIT
LOG KIT
NG
ULPG
Standard
Standard
Opening=
Opening=
3/16 in. (5 mm)
Full Open
1/4 in. (6 mm)
Full Open
NG
ULPG
Standard
Standard
Opening=
Opening=
3/8 in. (10 mm)
Full Open
3/8 in. (10 mm)
Full Open