Heat & Glo MTL-INSERT Owner's Manual
Heat & Glo MTL-INSERT Owner's Manual

Heat & Glo MTL-INSERT Owner's Manual

Installation and operation
Hide thumbs Also See for MTL-INSERT:
Table of Contents

Advertisement

Quick Links

Model:
MTL-Insert
• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING: If the information in these
instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of
this or any other appliance.
• What to do if you smell gas
- Do not try to light any appliance
- Do not touch any electrical switch. Do not
use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must be
installed in accordance with the manufacturer's instructions and
the manufactured home construction and safety standard, Title
24 CFR, Part 3280 or Standard for Installation in Mobile Homes,
CAN/CSA Z240MH.
This appliance is only for use with the type(s) of gas indicated
on the rating plate.
CAUTION
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09
Owner's Manual
Installation and Operation
• Leave this manual with
party responsible for use
and operation.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• DO NOT touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fi replace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other fl ammable
materials.
• Keep clothing, furniture, draperies and other fl ammable
materials away.
This appliance has been supplied with an integral barrier
to prevent direct contact with the fi xed glass panel. DO
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
In the Commonwealth of Massachusetts:
• installation must be performed by a licensed plumber
or gas fi tter;
• a CO detector shall be installed in the room where the
appliance is installed.
Installation and service of this appliance should be
performed by qualifi ed personnel. Hearth & Home
Technologies suggests NFI certifi ed or factory trained
professionals, or technicians supervised by an NFI
certifi ed professional.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MTL-INSERT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Heat & Glo MTL-INSERT

  • Page 1 fi tter; • a CO detector shall be installed in the room where the appliance is installed. Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09 Owner’s Manual Installation and Operation • Leave this manual with party responsible for use and operation.
  • Page 2: Homeowner Reference Information

    (Po. Col. d’eau) IN CANADA Mode l: 0-0000 FT . 0000-0000FT . (Modele): 00,000 00,000 00,000 00,000 Serial #XXXXX #XXXXX (Serie): Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09 Model Number MADE IN US A Serial Number XXXXXXXX XXXXXXXX...
  • Page 3: Table Of Contents

    E. Contact Information ......40 = Contains updated information. Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09...
  • Page 4: Listing And Code Approvals

    • A 110-120 VAC circuit for this product must be protected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks. Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09 WARNING...
  • Page 5: Getting Started

    • Installation and/or use of any component part not approved by Hearth & Home Technologies. Any such action may cause a fi re hazard. Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09 WARNING Inspect appliance and components for damage.
  • Page 6: Fireplace Size Requirements

    fl oor as tested for and as noted above. NOTE: For actual appliance dimensions refer to Section 15. TOP VIEW Minimum Appliance Size Location Inches Front Width 29-1/4 Rear Width 20-1/4 Depth 13-5/8 Height 20-1/4 Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09 MTL-INSERT Millimeters...
  • Page 7: Clearances

    INLET AIR EXHAUST VENT PIPE VENT PIPE MANTEL Figure 3.2 Clearances to Mantels or other Combustibles above Appliance 12 in. MAX. 15 in. MIN. MEASUREMENTS FROM TOP EDGE OF UNIT Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09...
  • Page 8: Termination Locations

    • Terminations MUST meet minimum clearances. • Exhaust gases are hot. • Nearby vents may draw fumes into house. HORIZONTAL OVERHANG VERTICAL WALL ROOF PITCH IS X/ 12 H (Min.) Ft. Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09...
  • Page 9: Vent Information And Diagrams

    TERMINATION CAP ADAPTOR EXHAUST VENT PIPE INSULATION SEAL INLET VENT AIR PIPE Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09 WARNING Fire Hazard. Explosion Risk. Asphyxiation Risk. Do NOT connect this gas appliance to a chimney fl ue serving a separate solid fuel or gas burning appliance.
  • Page 10: Installation Preparation

    Note: The MTL-INSERT does not ship standard with a junction box. In order to use a remote control, a junction box must be installed. Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09 WARNING Fire Risk. This fi replace has been converted for use with a gas fi...
  • Page 11: Installing Vent Pipe And Appliance

    TERMINATION INLET AIR VENT PIPE INLET AIR STARTING COLLAR STARTING COLLAR BRACKET EXHAUST STARTING COLLAR Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09 INLET AIR STARTING COLLAR LOCKING TAB STARTING COLLAR BRACKET EXHAUST STARTING COLLAR...
  • Page 12: Placing, Securing And Leveling The Appliance

    OR terminate within chimney. • Do NOT allow vent to sag below connection point to appliance. Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09 WARNING Fire Risk. Only an approved Hearth & Home Technologies surround may be used to cover integral grills on solid fuel burning fi...
  • Page 13: Installing Termination Cap

    THIS PIPE END! Note: Untwist the pipe while extending it, to achieve full 30’ length. Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09 CAUTION Sharp Edges • Wear protective gloves and safety glasses during installation. CLASS A PIPE Note: The LINK-DV4-30B system REQUIRES this insulation.
  • Page 14: Gas Information

    11.0 inches w.c. 14.0 inches w.c. 10.0 inches w.c. Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09 WARNING Gas Leak Risk • Support control when attaching pipe to prevent bending gas line.
  • Page 15 To identify the proper orifi ce size, check with the local gas utility. If installing this appliance at an elevation above 4500 feet (in Canada), check with local authorities. Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09...
  • Page 16: Electrical Information

    Figure 9.1. Follow directions included with the optional wall switch. ON/OFF SWITCH Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09 WARNING Wire 110V to electrical junction box. Do NOT wire 110V to valve.
  • Page 17: Optional Junction Box Installation

    Verify proper operation after servicing. WARNING Shock hazard. • Replace damaged wire with type 105º C rated wire. • Wire must have high temperature insulation. JUNCTION BOX ACCESS SIDEWALL Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09...
  • Page 18 UP TABS (ATTACH TO ANY METAL SURFACE) Figure 9.3 Fan/Rheostat Wire Diagram (Optional) Note: The MTL-INSERT does not ship standard with a fan. The fan is an optional accessory. Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09...
  • Page 19: Finishing

    INLET AIR 12 in. MAX. EXHAUST VENT PIPE VENT PIPE MANTEL 15 in. MIN. MEASUREMENTS FROM TOP EDGE OF UNIT Figure 10.1 Clearances to Mantels or other Combustibles above Appliance Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09...
  • Page 20: Appliance Setup

    • Save the remaining ember materials for use during appliance servicing. The embers provided should be enough for 3 to 5 applications. Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09...
  • Page 21: Positioning The Logs

    Pull the log forward until the log is stopped by the back edge of the burner. Log Set Assembly: LOGS-SXT BASEPAN BASEPAN Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09 TABS TABS 349-935 1/02...
  • Page 22 LOG #4 (SRV349-704): Place the bottom left corner of log #4 behind log #2 and rest its top right corner on log #1. The bottom left corner of the log rests in the square cut out of the base pan. Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09...
  • Page 23 #5. LOG #6 (SRV349-706): Position the "Y" end of log #6 into the cutout on log #4 and its opposite end into the groove on log #2. Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09...
  • Page 24: Glass Assembly

    Optimal fl ame appearance is dependent on the air shutter setting. Adjustments should be made by a qualified technician. Model MTL-INSERT Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09 GLASS ASSEMBLY BOTTOM LATCH 3/8 in. Full Open (3/4 in.)
  • Page 25: Operating Instructions

    Immediately call a qualifi ed service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09 WARNING HOT SURFACES! Glass and other surfaces are hot during operation AND cool down.
  • Page 26: Lighting Appliance

    For assistance or additional informa- tion, consult a qualifi ed installer, ser- vice agency or the gas supplier. Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09 LIGHTING INSTRUCTIONS 1. Turn off all electric power to the appliance.
  • Page 27: Check Pilot Flame Appearance

    This will help avoid setting off smoke detectors, and help eliminate any odors associated with the appliance’s initial burning. Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09 WARNING Glass door must be in place when appliance is operating.
  • Page 28: Frequently Asked Questions

    This noise does not affect the operation or longevity of the appliance. In a standing pilot system the pilot will always stay on. Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09 CAUTION • Open windows for air circulation.
  • Page 29: Troubleshooting

    Take a reading at the thermopile leads. The read- ing should be 325 millivolts minimum. Replace the thermopile if the reading is below the minimum. Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09 Corrective Action...
  • Page 30 Ensure that the glass is tightened properly on the unit, particularly on top corners. Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09 Corrective Action...
  • Page 31: Maintaining And Servicing Appliance

    Refer to maintenance instructions. • Combustible materials blocking cap may ignite. • Restricted air fl ow affects burner operation. Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09 CAUTION Handle glass assembly with care. NOTE: Clean glass after initial 3-4 hours operation.
  • Page 32 2. Replace batteries in remote transmitters and battery-powered receivers. 3. Verify batteries have been removed from battery back-up IPI systems to prevent premature battery failure or leaking. Maintenance Tasks Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09...
  • Page 33: Reference Materials

    MTL-INSERT LOCATION Inches Millimeters 29-1/32 20-5/32 10-3/32 32-5/16 26-11/16 11-5/8 22-23/32 20-7/16 21-1/8 8-7/16 REF Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09 ELECTRICAL ACCESS MODEL DIMENSIONS MTL-INSERT Inches Millimeters 2-5/16 4-7/16 5-5/32 2-5/32 13-23/32 2-1/2 5-9/32...
  • Page 34: Vent Kits Components

    FLEX-CNCT: Connector kit - 3 inch liner to 3 inch liner, one connector per kit. LINK-DV4-30B Installation WARNING: DO NOT BLOCK THIS PIPE END! Figure 15.3 Direct Vent Flex Liner Accessory Kits Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09 FLASH-DAMP LINK-ZC-ADP SVRLINK-ADP FLEX3-30 FLEX3-30/2 FLEX3-CNCT...
  • Page 35: Service Parts

    Part number list on following page. C. Service Parts Service Parts Diagram Log Set Assembly Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09 MTL-INSERT Beginning Manufacturing Date: Oct. 2007 Ending Manufacturing Date: ______...
  • Page 36 Pilot Orifi ce NG Pilot Orifi ce LP Regulator NG Regulator LP Additional service part numbers appear on following page. COMMENTS Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09 MTL-INSERT Stocked at Depot PART NUMBER LOGS-SXT SRV349-701...
  • Page 37 Bracket, Burner Support Burner Neck Gasket, Burner Neck Wiring Assembly Service Parts Valve Assembly Parts List Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09 MTL-INSERT Beginning Manufacturing Date: Oct. 2007 Ending Manufacturing Date: ______ COMMENTS PART NUMBER...
  • Page 38: Limited Lifetime Warranty

    D. Limited Lifetime Warranty Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09...
  • Page 39 D. Limited Lifetime Warranty (continued) Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09...
  • Page 40: Contact Information

    • Read, understand and follow these instructions for safe installation and operation. Printed in U.S.A. - Copyright 2009 Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09 • Leave this manual with party responsible for use and operation.

Table of Contents

Save PDF