4. Turn the gas shutoff handle to the "OFF" position
to shut off the gas supply.
If additional access is needed, proceed as follows:
5. Remove glass assembly from appliance by unlatch
ing the top spring latches from the glass frame and
lifting glass frame assembly out of the bottom brack
et.
6. Remove interior media and refractory from the unit
if already installed.
7. Remove the media tray. It is attached to the interior
firebox bottom with ten screws. See Figure 9.3.
8. Remove the two screws that attach the pilot to the
burner.
9. Remove the four screws securing the burner to
the firebox sides and disengage burner from
orifice. Remove burner. See Figure 9.3.
10. Remove the eight screws that secure the glass
window. Remove the glass window. Handle with
care. See Figure 9.4.
11. Remove light tray from appliance by lifting up and
out through the bottom glass opening.
PILOT SHIELD
BURNER ASSEMBLY
4836 & 6048
BURNER ASSEMBLY
7260 & 8472
Figure 9.3. Media Tray with Burner and Pilot Shield
Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15
40
MEDIA TRAY
-
-
Figure 9.4. Gas and Electrical Access - Remove Glass Window
GAS ACCESS
Figure 9.5. Gas Fitting Access with Vanity Panel Removed
GAS VALVE