The modem and antenna may be damaged if either come into contact with ground potentials 
other than the one in your application. Beware: ground potentials are not always what they 
appear to be. 
 
8.5 Radio Frequency (RF) exposure and SAR
Your wireless modem device is a low‐power radio transmitter and receiver (transceiver). When it is 
turned  on,  it  emits  low  levels  of  radio  frequency  energy  (also  known  as  radio  waves  or  radio 
frequency fields). 
 
Governments  around  the  world  have  adopted  comprehensive  international  safety  guidelines, 
developed  by  scientific  organizations  such  as  ICNIRP  (International  Commission  on  Non‐Ionizing 
Radiation  Protection)  and  IEEE  (The  Institute  of  Electrical  and  Electronics  Engineers  Inc.),  through 
periodic and thorough evaluation of scientific studies. These guidelines establish permitted levels of 
radio  wave  exposure  for  the  general  population.  The  levels  include  a  safety  margin  designed  to 
assure  the  safety  of  all  persons,  regardless  of  age  and  health,  and  to  account  for  any  variations  in 
measurements. 
 
Specific Absorption Rate (SAR) is the unit of measurement for the amount of radio frequency energy 
absorbed by the body when using a transceiver. The SAR value is determined at the highest certified 
power level in laboratory conditions, but the actual SAR level of the transceiver while operating can 
be  well  below  this  value.  This  is  because  the  transceiver  is  designed  to  use  the  minimum  power 
required to reach the network. 
 
The MTX‐3G‐JAVA wireless modem device has been approved for applications where the antenna is 
located  more  than  20cm  from  the  body.  In  all  other  configurations  the  user  is  responsible  for 
meeting the local SAR regulations. 
 
Users of the MTX‐3G‐JAVA wireless modem device are responsible for ensuring that they meet the 
SAR  regulatory  requirements  of  the  countries  in  which  they  intend  to  operate  the  device  and  that 
their  documentation  contains  the  relevant  SAR  declaration,  certification  information  and  user 
guidance as appropriate. 
 
8.6 Personal medical devices
Wireless modem  devices  may affect the operation of cardiac pacemakers, hearing aids and certain 
other implanted equipment. If a minimum distance of 15 cm (6 inches) is maintained between  the 
MTX‐3G‐JAVA modem radiating antenna and a pacemaker, the risk of interference is limited. If the 
user's  application  is  likely  to  be  situated  in  the  vicinity  of  personnel,  a  suitable  warning  should  be 
contained in the equipment manual to this effect
 
www.mtx‐terminals.com 
 
.
www.mtxm2m.com 
 
MTX M2M® by MATRIX ELECTRONICA S.L.U 
MTX‐3G‐JAVA Family
2015/10 v1.6  
/
Page 84