3.3 Storage conditions
The conditions stated below are only valid for modems in their original packed state in weather
protected, non‐temperature‐controlled storage locations. Normal storage time under these
conditions is a maximum of 12 months. The units will be delivered in a packaging that meets the
requirements according "IPD/JEDEC J‐STD‐033B.1" for Low Temperature Carriers.
Type
Air temperature: Low
High
Relative humidity: Low
High
Condensation
Air pressure: Low
High
Movement of surrounding air
Water: rain, dripping, icing and
frosting
Radiation: Solar
Heat
Chemically active substances
Mechanically active substances
Sinusoidal vibration:
Displacement
Acceleration
Frequency range
Shocks:
Shock spectrum
Duration
Acceleration
www.mtx‐terminals.com
Condition
Unit
‐30
ºC
+75
10
%
90 at 30ºC
90‐100 at 30ºC
70
kPa
106
1.0
m/s
Not allowed
‐
1120
W/m2
600
Not recommended
Not recommended
1.5
mm
5
m/s2
2‐9 9‐200
Hz
semi‐sinusoidal
1
ms
50
m/s2
www.mtxm2m.com
MTX M2M® by MATRIX ELECTRONICA S.L.U
MTX‐3G‐JAVA Family
Reference
ETS 300 019‐2‐1: T1.2, IEC 60068‐2‐1 Ab
ETS 300 019‐2‐1: T1.2, IEC 60068‐2‐2 Db
‐‐‐
ETS 300 019‐2‐1: T1.2, IEC 60068‐2‐56 Cb
ETS 300 019‐2‐1: T1.2, IEC 60068‐2‐30 Db
IEC TR 60271‐3‐1:1K4
IEC TR 60271‐3‐1:1K4
IEC TR 60271‐3‐1:1K4
‐
ETS 300 019‐2‐1: T1.2, IEC 60068‐2‐2Bb
ETS 300 019‐2‐1: T1.2, IEC 60068‐2‐2Bb
IEC TR 60271‐3‐1:1C1L
IEC TR 60271‐3‐1:1S1
IEC TR 60271‐3‐1:1M2
IEC 60068‐2‐27 Ea
2015/10 v1.6
/