Www.mtx-Terminals.com Www.mtxm2M.com 2015/10 V1.6 Page 4; Storage Conditions - MTX -3G-JAVA series User Manual

Table of Contents

Advertisement

 
3.3 Storage conditions
The conditions stated below are only valid for modems in their original packed state in weather 
protected, non‐temperature‐controlled storage locations. Normal storage time under these 
conditions is a maximum of 12 months. The units will be delivered in a packaging that meets the 
requirements according "IPD/JEDEC J‐STD‐033B.1" for Low Temperature Carriers. 
Type 
Air temperature: Low 
                               High 
Relative humidity: Low 
                                 High 
                                 Condensation 
Air pressure: Low 
                        High 
Movement of surrounding air 
Water: rain, dripping, icing and 
frosting 
Radiation: Solar 
                    Heat 
Chemically active substances 
Mechanically active substances 
Sinusoidal vibration: 
       Displacement 
       Acceleration 
       Frequency range 
Shocks: 
       Shock spectrum 
       Duration 
       Acceleration 
 
www.mtx‐terminals.com 
Condition 
Unit 
‐30 
ºC 
+75 
10 
90 at 30ºC 
90‐100 at 30ºC 
70 
kPa 
106 
1.0 
m/s 
Not allowed 
‐ 
1120 
W/m2 
600 
Not recommended 
 
Not recommended 
 
 
 
1.5 
mm 
m/s2 
2‐9  9‐200 
Hz 
 
 
semi‐sinusoidal 
 
ms 
50 
m/s2 
www.mtxm2m.com 
 
MTX M2M® by MATRIX ELECTRONICA S.L.U 
MTX‐3G‐JAVA Family
Reference 
ETS 300 019‐2‐1: T1.2, IEC 60068‐2‐1 Ab 
ETS 300 019‐2‐1: T1.2, IEC 60068‐2‐2 Db 
‐‐‐ 
ETS 300 019‐2‐1: T1.2, IEC 60068‐2‐56 Cb 
ETS 300 019‐2‐1: T1.2, IEC 60068‐2‐30 Db 
IEC TR 60271‐3‐1:1K4 
IEC TR 60271‐3‐1:1K4 
IEC TR 60271‐3‐1:1K4 
‐ 
ETS 300 019‐2‐1: T1.2, IEC 60068‐2‐2Bb 
ETS 300 019‐2‐1: T1.2, IEC 60068‐2‐2Bb 
IEC TR 60271‐3‐1:1C1L 
IEC TR 60271‐3‐1:1S1 
IEC TR 60271‐3‐1:1M2 
IEC 60068‐2‐27 Ea 
2015/10 v1.6  
/