4.1.2 5 way plug‐in terminal block (RS485 models)
A  5  way  plug‐in  terminal  block  connector  shared  with  RS485  bus,  as  shown  and  described  below, 
supplies and controls the D.C. power to the modem. 
 
The supply voltage, VCC, required by the modem is in the range of 6.5 to 40VDC. We recommend a 
12VDC power supply. The power supply has to be a single voltage source capable of providing a peak 
during an active transmission. The uplink burst causes strong ripples (drop) on the power lines. 
 
By default, the MTX‐3G‐JAVA‐RS485 will automatically switch on when power supply is applied at PIN 
4 and PIN 5.  
 
 
Pin 
Signal 
‐RxB 
+RxA 
AUTO ON 
VIN 
GND 
 
 
www.mtx‐terminals.com 
Direction 
Limits 
I/O 
I/O 
Input 
0‐VIN 
Input 
6.5‐40VDC  Positive power input 
Input 
  
www.mtxm2m.com 
MTX M2M® by MATRIX ELECTRONICA S.L.U 
MTX‐3G‐JAVA Family
Description 
RS485 B signal (see section 4.5 for details) 
RS485 A signal (see section 4.5 for details) 
Automatic Restart after Shutdown Enable Signal 
Negative power (ground) 