Operating Temperatures - MTX -3G-JAVA series User Manual

Table of Contents

Advertisement

 
3.2 Operating temperatures
Please note that the modem's lifetime, i.e., the MTTF (mean time to failure) may be reduced if 
operated outside the extended temperature range. 
 
Parameter 
Normal operation 
Extended operation
Automatic shutdown
 
1. Extended operation allows normal mode speech calls or data transmissions for a limited time 
until the automatic thermal shutdown mode takes effect. Within the extended temperature 
range (outside the operating temperature range) the specified electrical characteristics may 
be increased or decreased. 
2. Due  to  uncertainty  in  temperature  measurement,  a  tolerance  of  ±3ºC  on  the  stated 
shutdown thresholds may occur. 
 
Note  that  within  the  specified  operating  temperature  ranges  the  unit  temperature  may  vary  to  a 
great  extent  depending  on  the  operating  mode,  used  frequency  band,  radio  output  power  and 
current supply voltage. 
 
 
www.mtx‐terminals.com 
1
 
2
 
www.mtxm2m.com 
 
MTX M2M® by MATRIX ELECTRONICA S.L.U 
MTX‐3G‐JAVA Family
Min 
Typ 
Max 
Unit 
‐30 
+25 
+85 
°C 
‐40 
  
+90 
°C 
<‐40 
  
>+90 
°C 