60
en | Advanced Features
Functio
n Key
On/Off
On/Off
7.9.1

AutoHome Recalibration Operation

Recalibration occurs when the AutoDome loses its home position or after the specified time
interval has elapsed. Once a recalibration event occurs, the AutoDome will delay the start of
the recalibration for15 minutes to ensure that all manual commands have ceased. Manual
control is defined as a pan or tilt movement.
If after the initial 15-minute delay the AutoDome is still under manual control, the unit delays
the start of recalibration for another 15 minutes.
It is recommended to set the Inactivity (AUX ON 9) to Shot 1 or to Previous AUX so the
AutoDome returns to a preset position or starts a tour after the recalibration process is
complete.
The AutoHome recalibration behaves in the following manner under specific circumstances:
7.9.2

Using the AutoHome Recalibration

Use the following procedure for the initial setup of the AutoHome Recalibration:
4
2014.11 | 2.1 | F.01U.270.005
Comman
Command
d
Number
683
Recalibration Interval
684
Initial Offset Time
AutoTracker
If the AutoDome is actively tracking an object with AutoTracker when the interval elapses
or a loss of home is detected, the unit will delay recalibration until the AutoTracker stops
tracking.
Preset or Recorded Tour
If the AutoDome is performing a preset or playback of a recorded tour when the interval
elapses or a loss of home is detected, the unit will start the recalibration process
immediately. If the Inactivity command (AUX ON 9) is set to Return to AUX, the unit will
resume the tour after the recalibration process is complete.
Issue the AUX ON 680 command to check the status of the recalibration settings. This
command displays a status screen that shows the following information:
Description
Changes the homing recalibration interval.
Intervals are in 6-hour increments up to 72
hours.
Each On – increases interval by 6 hours
Each Off – decreases interval by 6 hours
Sets the initial offset time for the recalibration
interval. The offset time starts after the
Homing Calibration is enabled. The
recalibration interval begins its countdown
after the offset time.
Each On – increases offset time by 4 hours
Each Off – decreases offset time by 4 hours
Note: The offset time does not take effect